The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Diagnostic efficiency of troponin T measurements in acute myocardial infarction.
Abstract
BACKGROUND: The present study was designed to evaluate the efficiency of a newly developed troponin T enzyme immunoassay for the detection of acute myocardial infarction. METHODS AND RESULTS: The study comprised 388 patients admitted with chest pain and suspected myocardial infarction and 101 patients with skeletal muscle damage and additional suspected myocardial cell damage. Troponin T was elevated to more than twice the analytical sensitivity of the assay (0.5 microgram/l) in all patients with non-Q wave (range, 1.2-5 micrograms/l) and Q wave infarction (range, 3-220 micrograms/l). Troponin T appeared in serum as early as 3 hours after onset of pain in 50% of the patients and remained elevated in all patients for more than 130 hours, revealing release kinetics of both free cytosolic and structurally bound molecules. The diagnostic efficiency of troponin T was superior to that of creatine kinase-MB (98% versus 97%) and remained at 98% until 5.5 days after admission, if patients with unstable angina were excluded from analysis. In the 79 patients with unstable angina, troponin T was elevated (range, 0.55-3.1 micrograms/l) in at least one blood sample from each of 37 patients (56%). Circulating troponin T was correlated to the presence of reversible ST segment or T wave changes on the electrocardiogram (p less than 0.005) and to the frequency of in-hospital complications. In the 101 patients with skeletal muscle damage and suspected additional cardiac muscle damage, troponin T was the most useful test; its efficiency was 89% or 94% (depending on the discriminator value used) as compared with 63% for creatine kinase-MB. CONCLUSIONS: Thus, the data of the study indicate that the newly developed troponin T test improves the efficiency of serodiagnostic tools for the detection of myocardial cell necrosis as compared with conventionally used cardiac enzymes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Katus, H. (1989) · Journal of Molecular and Cellular Cardiology · doi:10.1016/0022-2828(89)90680-9 · Cited by 461
Self-citationCreatine kinase in serum: 1. Determination of optimum reaction conditions.
Szasz, G., Gruber, W., & Bernt, E. (1976) · Clinical Chemistry · doi:10.1093/clinchem/22.5.650 · Cited by 446
Comparison of amino acid sequence of troponin I from different striated muscles
Wilkinson, J. M., & Grand, R. J. A. (1978) · Nature · doi:10.1038/271031a0 · Cited by 364
LEE, T. H., & GOLDMAN, L. (1986) · Annals of Internal Medicine · doi:10.7326/0003-4819-105-2-221 · Cited by 264
Lott, J. A., & Stang, J. M. (1980) · Clinical Chemistry · doi:10.1093/clinchem/26.9.1241 · Cited by 208
Incidence and specificity of interference in two-site immunoassays.
Boscato, L. M., & Stuart, M. C. (1986) · Clinical Chemistry · doi:10.1093/clinchem/32.8.1491 · Cited by 208
Quantitation of creatine kinase isoenzymes in human tissues and sera by an immunological method
Jockers-Wretou, E., & Pfleiderer, G. (1975) · Clinica Chimica Acta · doi:10.1016/0009-8981(75)90441-6 · Cited by 197
Thompson, R. J., Jackson, A. P., & Langlois, N. E. I. (1986) · Clinical Chemistry · doi:10.1093/clinchem/32.3.476 · Cited by 122
Amino acid sequence of rabbit cardiac troponin T.
Pearlstone, J. R., Carpenter, M. R., & Smillie, L. B. (1986) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)75959-6 · Cited by 110
Turi, Z. G., Rutherford, J. D., Roberts, R., Muller, J. E., Jaffe, A. S., Rude, R. E., Parker, C. B., Raabe, D. S., Stone, P. H., Hartwell, T., et al. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)90954-3 · Cited by 57
Apple, F. S., Rogers, M. A., Sherman, W. M., & Ivy, J. L. (1984) · Clinica Chimica Acta · doi:10.1016/0009-8981(84)90359-0 · Cited by 50
Creatine kinase MB in cases of skeletal muscle trauma.
Schwartz, J. G., Prihoda, T. J., Stuckey, J. H., Gage, C. L., & Darnell, M. L. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.5.898 · Cited by 36
Thompson, W. G., Mahr, R. G., Yohannan, W. S., & Pincus, M. R. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.11.2208 · Cited by 24
Cited by
The Prognostic Value of Serum Troponin T in Unstable Angina
Hamm, C. W., Ravkilde, J., Gerhardt, W., Jørgensen, P., Peheim, E., Ljungdahl, L., Goldmann, B., & Katus, H. A. (1992) · New England Journal of Medicine · doi:10.1056/nejm199207163270302 · Cited by 953
Self-citationTroponin: the biomarker of choice for the detection of cardiac injury
Babuin, L., & Jaffe, A. S. (2005) · Canadian Medical Association Journal · doi:10.1503/cmaj.050141 · Cited by 686
Wu, A. H., Apple, F. S., Gibler, W. B., Jesse, R. L., Warshaw, M. M., & Valdes, R. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.7.1104 · Cited by 662
It’s Time for a Change to a Troponin Standard
Jaffe, A. S., Ravkilde, J., Roberts, R., Naslund, U., Apple, F. S., Galvani, M., & Katus, H. (2000) · Circulation · doi:10.1161/01.cir.102.11.1216 · Cited by 643
Self-citationNACB WRITING GROUP MEMBERS, Morrow, D. A., Cannon, C. P., Jesse, R. L., Newby, L. K., Ravkilde, J., Storrow, A. B., Wu, A. H. B., & Christenson, R. H. (2007) · Circulation · doi:10.1161/circulationaha.107.182882 · Cited by 610
Metadata
- Authors
- Katus, H. A., Remppis, A., Neumann, F. J., Scheffold, T., Diederich, K. W., Vinar, G., Noe, A., Matern, G., & Kuebler, W.
- Venue
- Circulation
- Published
- 1991-03
- Volume
- 83
- Issue
- 3
- Pages
- 902-912
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2075844027
- Cited by
- 814
- References
- 13
- FWCI
- 16.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.