The DOI matches its Crossref record.
Incidence and specificity of interference in two-site immunoassays.
Abstract
Using a modified "two-site" immunoradiometric assay, termed an "interference assay," we have demonstrated the occurrence of non-analyte antibody-binding substances in approximately 40% of serum samples. These substances multivalently bind antibodies from any of several species at a site other than the antigen-binding site. Using a two-site immunoradiometric assay for human choriogonadotropin, we have investigated their effect on analyte quantification. In this system these antibody-binding substances mimic the presence of analyte; when analyte is actually present, they can also cause over- or underestimates. Addition of excess nonspecific immunoglobulin from an appropriate species eliminates this interference. However, the amount of nonspecific immunoglobulin added to an assay system may not always be enough to block interference in all samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diagnostic efficiency of troponin T measurements in acute myocardial infarction.
Katus, H. A., Remppis, A., Neumann, F. J., Scheffold, T., Diederich, K. W., Vinar, G., Noe, A., Matern, G., & Kuebler, W. (1991) · Circulation · doi:10.1161/01.cir.83.3.902 · Cited by 814
Human Anti-Animal Antibody Interferences in Immunological Assays
Kricka, L. J. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.7.942 · Cited by 586
Katus, H. (1989) · Journal of Molecular and Cellular Cardiology · doi:10.1016/0022-2828(89)90680-9 · Cited by 461
A Decade of Development in Immunoassay Methodology
Gosling, J. P. (1990) · Clinical Chemistry · doi:10.1093/clinchem/36.8.1408 · Cited by 457
Park, J. Y., & Kricka, L. J. (2013) · The Immunoassay Handbook · doi:10.1016/b978-0-08-097037-0.00027-0 · Cited by 365
Metadata
- Authors
- Boscato, L. M., & Stuart, M. C.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1986-08-01
- Volume
- 32
- Issue
- 8
- Pages
- 1491-1495
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1845228072
- Cited by
- 208
- References
- 0
- FWCI
- 8.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Incidence and specificity of interference in two-site immunoassays. https://app.cochat.ai/papers/10.1093/clinchem/32.8.1491
- The paper
- Boscato, L. M., & Stuart, M. C. (1986). Incidence and specificity of interference in two-site immunoassays. Clinical Chemistry. https://doi.org/10.1093/clinchem/32.8.1491
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.