The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Exercise Echocardiography or Exercise SPECT Imaging?: A Meta-analysis of Diagnostic Test Performance
Abstract
CONTEXT: Cardiac imaging has advanced rapidly, providing clinicians with several choices for evaluating patients with suspected coronary artery disease, but few studies compare modalities directly. OBJECTIVES: To review the contemporary literature and to compare the diagnostic performance of exercise echocardiography (ECHO) and exercise single-photon emission computed tomography (SPECT) imaging in the diagnosis of coronary artery disease. DATA SOURCES: Studies published between January 1990 and October 1997 identified from MEDLINE search; bibliographies of reviews and original articles; and suggestions from experts in each area. STUDY SELECTION: Articles were included if they discussed exercise ECHO and/or exercise SPECT imaging with thallous chloride TI 201 (thallium) or technetium Tc 99m sestamibi for detection and/or evaluation of coronary artery disease, if data on coronary angiography were presented as the reference test, and if the absolute numbers of true-positive, false-negative, true-negative, and false-positive observations were available or derivable from the data presented. Studies performed exclusively in patients after myocardial infarction, after percutaneous transluminal coronary angioplasty, after coronary artery bypass grafting, or with recent unstable coronary syndromes were excluded. DATA EXTRACTION: Clinical variables, technical factors, and test performance were independently extracted by 2 reviewers on a standardized spreadsheet. Discrepancies were resolved by consensus. RESULTS: Forty-four articles met inclusion criteria. In pooled data weighted by the sample size of each study, exercise ECHO had a sensitivity of 85% (95% confidence interval [CI], 83%-87%) with a specificity of 77% (95% CI, 74%-80%). Exercise SPECT yielded a similar sensitivity of 87% (95% CI, 86%-88%) but a lower specificity of 64% (95% CI, 60%-68%). In a summary receiver operating characteristic model comparing exercise ECHO performance to exercise SPECT, exercise ECHO was associated with significantly better discriminatory power (parameter estimate, 1.18; 95% CI, 0.71-1.65), when adjusted for age, publication year, and a setting including known coronary artery disease for SPECT studies. In models comparing the discriminatory abilities of exercise ECHO and exercise SPECT vs exercise testing without imaging, both ECHO and SPECT performed significantly better than exercise testing. The incremental improvement in performance was greater for ECHO (3.43; 95% CI, 2.74-4.11) than for SPECT (1.49; 95% CI, 0.91-2.08). CONCLUSIONS: Exercise ECHO and exercise SPECT have similar sensitivities for the detection of coronary artery disease, but exercise ECHO has better specificity and, therefore, higher overall discriminatory capabilities as used in contemporary practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of diagnostic tests when disease verification is subject to selection bias
Begg, C. B., & Greenes, R. A. (1983) · Biometrics · doi:10.2307/2530820 · Cited by 708
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
2024 ESC Guidelines for the management of chronic coronary syndromes
Vrints, C., Andreotti, F., Koskinas, K. C., Rossello, X., Adamo, M., Ainslie, J., Banning, A. P., Budaj, A., Buechel, R. R., Chiariello, G. A., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae177 · Cited by 2,774
Outcomes of Anatomical versus Functional Testing for Coronary Artery Disease
Douglas, P. S., Hoffmann, U., Patel, M. R., Mark, D. B., Al-Khalidi, H. R., Cavanaugh, B., Cole, J., Dolor, R. J., Fordyce, C. B., Huang, M., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1415516 · Cited by 1,543
Self-citationCoronary CT Angiography and 5-Year Risk of Myocardial Infarction
The SCOT-HEART Investigators (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1805971 · Cited by 1,390
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318277d6a0 · Cited by 845
Self-citation
Metadata
- Authors
- Fleischmann, K. E., Hunink, M. G. M., Kuntz, K. M., & Douglas, P. S.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 1998-09-09
- Volume
- 280
- Issue
- 10
- Pages
- 913
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2158335943
- Cited by
- 490
- References
- 1
- FWCI
- 24.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Exercise Echocardiography or Exercise SPECT Imaging?: A Meta-analysis of Diagnostic Test Performance. https://app.cochat.ai/papers/10.1001/jama.280.10.913
- The paper
- Fleischmann, K. E., Hunink, M. G. M., Kuntz, K. M., & Douglas, P. S. (1998). Exercise Echocardiography or Exercise SPECT Imaging?: A Meta-analysis of Diagnostic Test Performance. JAMA. https://doi.org/10.1001/jama.280.10.913
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.