Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 490

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Exercise Echocardiography or Exercise SPECT Imaging?: A Meta-analysis of Diagnostic Test Performance

Fleischmann, Kirsten E., Hunink, Maria G. M., Kuntz, Karen M., Douglas, Pamela S.·1998·JAMA

Abstract

CONTEXT: Cardiac imaging has advanced rapidly, providing clinicians with several choices for evaluating patients with suspected coronary artery disease, but few studies compare modalities directly. OBJECTIVES: To review the contemporary literature and to compare the diagnostic performance of exercise echocardiography (ECHO) and exercise single-photon emission computed tomography (SPECT) imaging in the diagnosis of coronary artery disease. DATA SOURCES: Studies published between January 1990 and October 1997 identified from MEDLINE search; bibliographies of reviews and original articles; and suggestions from experts in each area. STUDY SELECTION: Articles were included if they discussed exercise ECHO and/or exercise SPECT imaging with thallous chloride TI 201 (thallium) or technetium Tc 99m sestamibi for detection and/or evaluation of coronary artery disease, if data on coronary angiography were presented as the reference test, and if the absolute numbers of true-positive, false-negative, true-negative, and false-positive observations were available or derivable from the data presented. Studies performed exclusively in patients after myocardial infarction, after percutaneous transluminal coronary angioplasty, after coronary artery bypass grafting, or with recent unstable coronary syndromes were excluded. DATA EXTRACTION: Clinical variables, technical factors, and test performance were independently extracted by 2 reviewers on a standardized spreadsheet. Discrepancies were resolved by consensus. RESULTS: Forty-four articles met inclusion criteria. In pooled data weighted by the sample size of each study, exercise ECHO had a sensitivity of 85% (95% confidence interval [CI], 83%-87%) with a specificity of 77% (95% CI, 74%-80%). Exercise SPECT yielded a similar sensitivity of 87% (95% CI, 86%-88%) but a lower specificity of 64% (95% CI, 60%-68%). In a summary receiver operating characteristic model comparing exercise ECHO performance to exercise SPECT, exercise ECHO was associated with significantly better discriminatory power (parameter estimate, 1.18; 95% CI, 0.71-1.65), when adjusted for age, publication year, and a setting including known coronary artery disease for SPECT studies. In models comparing the discriminatory abilities of exercise ECHO and exercise SPECT vs exercise testing without imaging, both ECHO and SPECT performed significantly better than exercise testing. The incremental improvement in performance was greater for ECHO (3.43; 95% CI, 2.74-4.11) than for SPECT (1.49; 95% CI, 0.91-2.08). CONCLUSIONS: Exercise ECHO and exercise SPECT have similar sensitivities for the detection of coronary artery disease, but exercise ECHO has better specificity and, therefore, higher overall discriminatory capabilities as used in contemporary practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.280.10.913

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 490

Metadata

Authors
Fleischmann, K. E., Hunink, M. G. M., Kuntz, K. M., & Douglas, P. S.
Venue
JAMA
Published
1998-09-09
Volume
280
Issue
10
Pages
913
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2158335943
Cited by
490
References
1
FWCI
24.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Exercise Echocardiography or Exercise SPECT Imaging?: A Meta-analysis of Diagnostic Test Performance. https://app.cochat.ai/papers/10.1001/jama.280.10.913
The paper
Fleischmann, K. E., Hunink, M. G. M., Kuntz, K. M., & Douglas, P. S. (1998). Exercise Echocardiography or Exercise SPECT Imaging?: A Meta-analysis of Diagnostic Test Performance. JAMA. https://doi.org/10.1001/jama.280.10.913

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.