Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 258

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Quantification of regional myocardial blood flow using 13N-ammonia and reoriented dynamic positron emission tomographic imaging.

Kuhle, W G, Porenta, G, Huang, S C, Buxton, D, Gambhir, S S, Hansen, H, Phelps, M E, Schelbert, H R·1992·Circulation

Abstract

BACKGROUND: Regional myocardial blood flow has been quantified using transaxial positron emission tomographic (PET) imaging and tracer kinetic modeling. However, the use of transaxial images limits the accuracy of regional partial volume corrections and the localization of the quantified regional flow values. The purpose of the present study was to overcome both problems by calculating regional flows from reoriented short-axis PET images. METHODS AND RESULTS: Twelve experiments were performed in four dogs. 13N-ammonia was injected intravenously while microspheres were administered into the left atrium during baseline, hyperemic, and low-flow conditions. Serial transaxial frames were acquired with a 15-plane PET scanner and reoriented into short-axis frames. The arterial input function and eight regional myocardial tissue activity curves were derived from the reoriented frames. The arterial input functions were corrected for ammonia metabolites, and the myocardial tissue curves were corrected for spillover of activity, partial volume effects, and heterogeneities in the image's spatial resolution introduced during reorientation. Corrections for regional partial volume were based on estimates of the regional myocardial activity thickness derived from reoriented diastolic images of the heart. The myocardial 13N-ammonia kinetics were described with a two-pool compartmental model. Values of regional myocardial blood flow by PET correlated linearly with those by microspheres (slope, 0.94; y intercept, 0.06 ml/min/g; r = 0.93) over a wide range of flows. CONCLUSIONS: Regional myocardial blood flow can be measured accurately and noninvasively from serially acquired and reoriented short-axis 13N-ammonia images, thus overcoming limitations inherent to the use of transaxially acquired images and permitting a more complete evaluation of regional blood flows throughout the left ventricular myocardium.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.86.3.1004

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 258

Metadata

Authors
Kuhle, W. G., Porenta, G., Huang, S. C., Buxton, D., Gambhir, S. S., Hansen, H., Phelps, M. E., & Schelbert, H. R.
Venue
Circulation
Published
1992-09
Volume
86
Issue
3
Pages
1004-1017
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1967527761
Cited by
258
References
9
FWCI
8.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of regional myocardial blood flow using 13N-ammonia and reoriented dynamic positron emission tomographic imaging. https://app.cochat.ai/papers/10.1161/01.cir.86.3.1004
The paper
Kuhle, W. G., Porenta, G., Huang, S. C., Buxton, D., Gambhir, S. S., Hansen, H., Phelps, M. E., & Schelbert, H. R. (1992). Quantification of regional myocardial blood flow using 13N-ammonia and reoriented dynamic positron emission tomographic imaging. Circulation. https://doi.org/10.1161/01.cir.86.3.1004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.