The DOI matches its Crossref record.
The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting.
Abstract
BACKGROUND: We evaluated native coronary arteries treated by directional coronary atherectomy or balloon-expandable stent placement in an effort to derive a quantitative geometric model relating the luminal diameter immediately after intervention to that present 6 months later. The minimal luminal diameter of each lesion was measured before and immediately after intervention in 102 single Palmaz-Schatz stents and 134 directional atherectomies, 192 (81%) of which had repeat angiographic measurement of minimal luminal diameter 6 months after the intervention. The immediate enlargement in luminal diameter produced by the intervention (acute gain) and the subsequent reduction in luminal diameter from the time of intervention to 6 months of follow-up (late loss) were calculated. METHODS AND RESULTS: Luminal diameter increased from 0.69 +/- 0.40 mm to 3.11 +/- 0.64 mm (acute gain, 2.41 +/- 0.64 mm) after intervention, providing an immediate postprocedure residual stenosis of 1 +/- 14% relative to a reference diameter of 3.13 +/- 0.65 mm. At 6-month follow-up, the late luminal diameter was 1.97 +/- 0.92 mm (late loss, 1.13 +/- 0.89 mm), yielding a late diameter stenosis of 36 +/- 26%. The restenosis rate (according to the traditional definition of diameter stenosis > or = 50%) was 30%. Multivariable analysis demonstrated that late luminal diameter (p = 0.02), late percent stenosis (p = 0.04), and restenosis (according to a > 50% definition, p = 0.04) were each strongly associated with the luminal diameter present immediately after the procedure. Whereas late luminal diameter was also influenced by reference artery size and the vessel treated (left anterior descending versus right coronary artery), reference vessel size was rejected by the multivariable models of late percent stenosis and binary restenosis after they were adjusted for the effect of postprocedure luminal diameter. Once adjusted for postprocedure luminal diameter, neither late luminal diameter nor late loss was found to be independently determined by which device was used (atherectomy versus stents). Rather, late loss was determined independently by the immediate postprocedure luminal diameter (p = 0.005) and the postprocedure percent stenosis (p = 0.02). Although late loss thus increased with acute gain, the net beneficial effect of increased acute gain was maintained: Late loss was only a fraction (0.47) of acute gain, so the ability of a larger postprocedure luminal diameter to reduce the probability of subsequent restenosis was preserved. CONCLUSIONS: This quantitative model demonstrates that the late coronary lumen diameter and the probability of restenosis after Palmaz-Schatz stenting or directional atherectomy are influenced strongly by the lumen diameter present immediately after the procedure rather than by the specific device used. Although the influence of a larger acute result on reduced restenosis appears to be well established in this treatment population, the interplay among the multiple other biological influences on restenosis limits the ability to predict the probability of restenosis for the individual patient based on a large acute result alone. Future studies of restenosis, however, can further refine this multivariable quantitative model by adjusting for the effects of other clinical variables, mechanical interventions, or drug therapies in addition to the clear effect of postprocedure luminal diameter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Patterns and Mechanisms of In-Stent Restenosis: A Serial Intravascular Ultrasound Study
Hoffmann, R., Mintz, G. S., Dussaillant, G. R., Popma, J. J., Pichard, A. D., Satler, L. F., Kent, K. M., Griffin, J., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.6.1247 · Cited by 1,247
Endovascular Stent Design Dictates Experimental Restenosis and Thrombosis
Rogers, C., & Edelman, E. R. (1995) · Circulation · doi:10.1161/01.cir.91.12.2995 · Cited by 543
Cassese, S., Byrne, R. A., Tada, T., Pinieck, S., Joner, M., Ibrahim, T., King, L. A., Fusaro, M., Laugwitz, K.-L., & Kastrati, A. (2014) · Heart · doi:10.1136/heartjnl-2013-304933 · Cited by 438
Clinical and quantitative coronary angiographic predictors of coronary restenosis
Mercado, N., Boersma, E., Wijns, W., Gersh, B. J., Morillo, C. A., de Valk, V., van Es, G.-A., Grobbee, D. E., & Serruys, P. W. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01431-0 · Cited by 175
Metadata
- Authors
- Kuntz, R. E., Safian, R. D., Carrozza, J. P., Fishman, R. F., Mansour, M., & Baim, D. S.
- Venue
- Circulation
- Published
- 1992-12
- Volume
- 86
- Issue
- 6
- Pages
- 1827-1835
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2012599291
- Cited by
- 359
- References
- 0
- FWCI
- 29.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting. https://app.cochat.ai/papers/10.1161/01.cir.86.6.1827
- The paper
- Kuntz, R. E., Safian, R. D., Carrozza, J. P., Fishman, R. F., Mansour, M., & Baim, D. S. (1992). The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting. Circulation. https://doi.org/10.1161/01.cir.86.6.1827
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.