Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 543

The DOI matches its Crossref record.

Endovascular Stent Design Dictates Experimental Restenosis and Thrombosis

Rogers, Campbell, Edelman, Elazer R.·1995·Circulation

Abstract

Background Vascular interventions that maximize initial lumen diameter provoke extensive neointimal hyperplasia but minimize its effects, causing long-term lumen size to be greater. Nevertheless, interventions such as endovascular stents, which increase lumen size above that achieved with balloon angioplasty, are subject to frequent thrombosis and restenosis. It has been unclear whether the response to stent-induced injury is determined solely by the degree of stent-induced arterial expansion or whether the geometric configuration of the stent or the material left in contact with the vessel wall also contribute. Methods and Results We examined the vascular response to steel stents deployed in denuded rabbit iliac arteries for 14 days. In one set of experiments, the effects of stent configuration were examined, holding diameter, mass, surface area, and stent surface material constant. In another set, stent surface material was changed, with mass, configuration, and diameter unaltered. Changing stent configuration to reduce strut-strut intersections by 29% without affecting mass or surface area reduced vascular injury by 42%, thrombosis by 69%, and neointimal hyperplasia by 38%. Monocyte adhesion to stented arteries correlated linearly with vascular trauma and neointimal hyperplasia ( r =.96, P <.01 for each). When the stainless steel surface was coated with an inert polymer material, vascular injury and neointimal hyperplasia were unchanged, but thrombosis was eliminated. Conclusions Surface material and geometric configuration of stents may be more important than postplacement diameter in determining neointimal hyperplasia and thrombosis. Alterations in configuration affect vascular injury and neointimal hyperplasia, while surface material plays a greater role in thrombosis. Monocytes may be important modulators of stent-induced intimal thickening. Clinical confirmation of these findings may alter coronary stent deployment techniques and future stent designs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.91.12.2995

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 543

Metadata

Authors
Rogers, C., & Edelman, E. R.
Venue
Circulation
Published
1995-06-15
Volume
91
Issue
12
Pages
2995-3001
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1976855765
Cited by
543
References
0
FWCI
21.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Endovascular Stent Design Dictates Experimental Restenosis and Thrombosis. https://app.cochat.ai/papers/10.1161/01.cir.91.12.2995
The paper
Rogers, C., & Edelman, E. R. (1995). Endovascular Stent Design Dictates Experimental Restenosis and Thrombosis. Circulation. https://doi.org/10.1161/01.cir.91.12.2995

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.