Ultrasound-assisted cannulation of the internal jugular vein. A prospective comparison to the external landmark-guided technique.
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Central venous access is an essential part of patient management in many clinical settings and is usually achieved with a blinded, external landmark-guided technique. The purpose of this study is to evaluate whether an ultrasound technique can improve on the traditional method. METHODS AND RESULTS: We prospectively evaluated an ultrasound-guided method in 302 patients undergoing internal jugular venous cannulation and compared the results with 302 patients in whom an external landmark-guided technique was used. Ultrasound was used exclusively in an additional 626 patients. Cannulation of the internal jugular vein was achieved in all patients (100%) using ultrasound and in 266 patients (88.1%) using the landmark-guided technique (p < 0.001). The vein was entered on the first attempt in 78% of patients using ultrasound and in 38% using the landmark technique (p < 0.001). Average access time (skin to vein) was 9.8 seconds (2-68 seconds) by the ultrasound approach and 44.5 seconds (2-1,000 seconds) by the landmark approach (p < 0.001). Using ultrasound, puncture of the carotid artery occurred in 1.7% of patients, brachial plexus irritation in 0.4%, and hematoma in 0.2%. In the external landmark group, puncture of the carotid artery occurred in 8.3% of patients (p < 0.001), brachial plexus irritation in 1.7% (p < 0.001), and hematoma in 3.3% (p < 0.001). CONCLUSIONS: Ultrasound-guided cannulation of the internal jugular vein significantly improves success rate, decreases access time, and reduces complication rate. These results suggest that this technique may be preferred in complicated cases or when access problems are anticipated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrasound Guidance Improves the Success Rate of Internal Jugular Vein Cannulation
Mallory, D. L., McGee, W. T., Shawker, T. H., Brenner, M., Bailey, K. R., Evans, R. G., Parker, M. M., Farmer, J. C., & Parillo, J. E. (1990) · Chest · doi:10.1378/chest.98.1.157 · Cited by 264
Cited by
Cooper, L. T., Baughman, K. L., Feldman, A. M., Frustaci, A., Jessup, M., Kuhl, U., Levine, G. N., Narula, J., Starling, R. C., Towbin, J., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.186093 · Cited by 1,030
“Sonographic techniques to identify the location, size, and respirophasic variation in size of the internal jugular vein decrease the duration of the procedure and complications (9,10).”
Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature
Randolph, A. G., Cook, D. J., Gonzales, C. A., & Pribble, C. G. (1996) · Critical Care Medicine · doi:10.1097/00003246-199612000-00020 · Cited by 852
International evidence-based recommendations on ultrasound-guided vascular access
Lamperti, M., Bodenham, A. R., Pittiruti, M., Blaivas, M., Augoustides, J. G., Elbarbary, M., Pirotte, T., Karakitsos, D., LeDonne, J., Doniger, S., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2597-x · Cited by 834
The Role of Endomyocardial Biopsy in the Management of Cardiovascular Disease
Cooper, L. T., Baughman, K. L., Feldman, A. M., Frustaci, A., Jessup, M., Kuhl, U., Levine, G. N., Narula, J., Starling, R. C., Towbin, J., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.008 · Cited by 672
Karakitsos, D., Labropoulos, N., De Groot, E., Patrianakos, A. P., Kouraklis, G., Poularas, J., Samonis, G., Tsoutsos, D. A., Konstadoulakis, M. M., & Karabinis, A. (2006) · Critical Care · doi:10.1186/cc5101 · Cited by 639
Complications and Failures of Subclavian-Vein Catheterization
(1995) · New England Journal of Medicine · doi:10.1056/nejm199506083322313 · Cited by 626
Venous Thromboembolism Associated With Long-Term Use of Central Venous Catheters in Cancer Patients
Verso, M., & Agnelli, G. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.08.008 · Cited by 605
Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization
Brass, P., Hellmich, M., Kolodziej, L., Schick, G., & Smith, A. F. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006962.pub2 · Cited by 476
Cooper, L. T., Baughman, K. L., Feldman, A. M., Frustaci, A., Jessup, M., Kuhl, U., Levine, G. N., Narula, J., Starling, R. C., Towbin, J., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm456 · Cited by 464
Costantino, T. G., Parikh, A. K., Satz, W. A., & Fojtik, J. P. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.12.026 · Cited by 435
Troianos, C. A., Hartman, G. S., Glas, K. E., Skubas, N. J., Eberhardt, R. T., Walker, J. D., & Reeves, S. T. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.09.021 · Cited by 420
Leung, J., Duffy, M., & Finckh, A. (2006) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.01.011 · Cited by 342
Milling, T. J., Rose, J., Briggs, W. M., Birkhahn, R., Gaeta, T. J., Bove, J. J., & Melniker, L. A. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000171533.92856.e5 · Cited by 334
Complications of Central Venous Catheterization
Kusminsky, R. E. (2007) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2007.01.039 · Cited by 330
Verghese, S. T., McGill, W. A., Patel, R. I., Sell, J. E., Midgley, F. M., & Ruttimann, U. E. (1999) · Anesthesiology · doi:10.1097/00000542-199907000-00013 · Cited by 324
Troianos, C. A., Hartman, G. S., Glas, K. E., Skubas, N. J., Eberhardt, R. T., Walker, J. D., & Reeves, S. T. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3182407cd8 · Cited by 321
Keyes, L. E., Frazee, B. W., Snoey, E. R., Simon, B. C., & Christy, D. (1999) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(99)70095-8 · Cited by 291
Ultrasound-guidance vs. standard technique in difficult vascular access patients by ed technicians
Bauman, M., Braude, D., & Crandall, C. (2009) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2008.02.005 · Cited by 160
Catheter-Associated Thrombosis in Patients With Malignancy
Shivakumar, S. P., Anderson, D. R., & Couban, S. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2009.22.6126 · Cited by 77
Metadata
- Authors
- Denys, B. G., Uretsky, B. F., & Reddy, P. S.
- Venue
- Circulation
- Published
- 1993-05
- Volume
- 87
- Issue
- 5
- Pages
- 1557-1562
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2091639018
- Cited by
- 543
- References
- 1
- FWCI
- 15.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.