CoChat

Ventricular systolic assessment in patients with dilated cardiomyopathy by preload-adjusted maximal power. Validation and noninvasive application.

Sharir, T, Feldman, M D, Haber, H, Feldman, A M, Marmor, A, Becker, L C, Kass, D A · 1994 · Circulation
Cited by 80

The DOI matches its Crossref record.

Abstract

BACKGROUND: Noninvasive cardiac-specific analysis of contractile function in patients with dilated heart failure remains problematic. This study tests whether maximal power divided by the square of end-diastolic volume (PWRmx/EDV2, or preload-adjusted PWRmx) can provide such assessment. METHODS AND RESULTS: To validate the load insensitivity of the PWRmx index and determine its response to contractile change, 24 subjects with chronic dilated cardiomyopathy underwent invasive pressure-volume catheterization study using the conductance catheter technique. Preload was transiently reduced by 30% using balloon occlusion of the inferior vena cava, and afterload impedance was lowered by 50%, induced by a bolus injection of nitroglycerin. Contractile state was varied by intravenous dobutamine, verapamil, or esmolol. PWRmx was calculated from the simultaneous product of ventricular pressure and rate of volume change (dV/dt), the latter derived from the volume catheter signal. PWRmx varied directly with preload but was minimally influenced by afterload. However, PWRmx/EDV2 was not significantly altered by either loading change. PWRmx/EDV2 did vary with contractility, correlating closely with changes in the end-systolic pressure-volume relation (r = .91, P < .001). To test the noninvasive application of this index, 12 additional patients were studied, with PWRmx/EDV2 derived from nuclear ventriculography combined with a novel method to measure central arterial pressures. Subjects received intravenous nitroprusside or dobutamine in random order. Ejection fraction increased similarly with both agents (+42.9 +/- 8.9% for dobutamine and +29.4 +/- 5.3% for nitroprusside, both P < .01). In contrast, PWRmx/EDV2 did not significantly change with nitroprusside but increased by 126 +/- 16.1% with dobutamine (P < .01). CONCLUSIONS: Preload-adjusted PWRmx is a steady-state index of ventricular systolic function that is sensitive to inotropic state and minimally influenced by physiological changes in afterload impedance or volume load. It appears useful for noninvasive cardiac-specific analysis of acute drug effects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.89.5.2045

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Sharir, T., Feldman, M. D., Haber, H., Feldman, A. M., Marmor, A., Becker, L. C., & Kass, D. A.
Venue
Circulation
Published
1994-05
Volume
89
Issue
5
Pages
2045-2053
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1979487910
Cited by
80
References
0
FWCI
2.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.