Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 302

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Exclusion of atrial thrombus by transesophageal echocardiography does not preclude embolism after cardioversion of atrial fibrillation. A multicenter study.

Black, I W, Fatkin, D, Sagar, K B, Khandheria, B K, Leung, D Y, Galloway, J M, Feneley, M P, Walsh, W F, Grimm, R A, Stollberger, C·1994·Circulation

Abstract

BACKGROUND: Transesophageal echocardiography (TEE) has been used recently to detect atrial thrombi before cardioversion of atrial arrhythmias. It has been assumed that embolic events after cardioversion result from embolism of preexisting atrial thrombi that are accurately detected by TEE. This study examined the clinical and echocardiographic findings in patients with embolism after cardioversion of atrial fibrillation despite exclusion of atrial thrombi by TEE. METHODS AND RESULTS: Clinical and echocardiographic data in 17 patients with embolic events after TEE-guided electrical (n = 16) or pharmacological (n = 1) cardioversion were analyzed. All 17 patients had nonvalvular atrial fibrillation, including four patients with lone atrial fibrillation. TEE before cardioversion showed left atrial spontaneous echo contrast in five patients and did not show atrial thrombus in any patient. Cardioversion resulted in return to sinus rhythm without immediate complication in all patients. Thirteen patients had cerebral embolic events and four patients had peripheral embolism occurring 2 hours to 7 days after cardioversion. None of the patients were therapeutically anticoagulated at the time of embolism. New or increased left atrial spontaneous echo contrast was detected in four of the five patients undergoing repeat TEE after cardioversion including one patient with a new left atrial appendage thrombus. CONCLUSIONS: Embolism may occur after cardioversion of atrial fibrillation in inadequately anticoagulated patients despite apparent exclusion of preexisting atrial thrombus by TEE. These findings suggest de novo atrial thrombosis after cardioversion or imperfect sensitivity of TEE for atrial thrombi and suggest that screening by TEE does not obviate the requirement for anticoagulant therapy at the time of and after cardioversion. A randomized clinical trial is needed to compare conventional anticoagulant management with a TEE-guided strategy including anticoagulation after cardioversion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.89.6.2509

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 302

Metadata

Authors
Black, I. W., Fatkin, D., Sagar, K. B., Khandheria, B. K., Leung, D. Y., Galloway, J. M., Feneley, M. P., Walsh, W. F., Grimm, R. A., & Stollberger, C.
Venue
Circulation
Published
1994-06
Volume
89
Issue
6
Pages
2509-2513
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2007887497
Cited by
302
References
28
FWCI
16.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Exclusion of atrial thrombus by transesophageal echocardiography does not preclude embolism after cardioversion of atrial fibrillation. A multicenter study. https://app.cochat.ai/papers/10.1161/01.cir.89.6.2509
The paper
Black, I. W., Fatkin, D., Sagar, K. B., Khandheria, B. K., Leung, D. Y., Galloway, J. M., Feneley, M. P., Walsh, W. F., Grimm, R. A., & Stollberger, C. (1994). Exclusion of atrial thrombus by transesophageal echocardiography does not preclude embolism after cardioversion of atrial fibrillation. A multicenter study. Circulation. https://doi.org/10.1161/01.cir.89.6.2509

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.