The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Three-dimensional left ventricular deformation in hypertrophic cardiomyopathy.
Open accessAbstract
BACKGROUND: In hypertrophic cardiomyopathy, ejection fraction is normal or increased, and force-length relations are reduced. However, three-dimensional (3D) motion and deformation in vivo have not been assessed in this condition. We have reconstructed the 3D motion of the left ventricle (LV) during systole in 7 patients with hypertrophic cardiomyopathy (HCM) and 12 normal volunteers by use of magnetic resonance tagging. METHODS AND RESULTS: Transmural tagging stripes were automatically tracked to subpixel resolution with an active contour model. A 3D finite-element model was used to interpolate displacement information between short- and long-axis slices and register data on a regional basis. Displacement and strain data were averaged into septal, posterior, lateral, and anterior regions at basal, midventricular, and apical levels. Radial motion (toward the central long axis) decreased slightly in patients with HCM, whereas longitudinal displacement (parallel to the long axis) of the base toward the apex was markedly reduced: 7.5 +/- 2.5mm (SD) versus 12.5 +/- 2.0 mm, P < .001. Circumferential and longitudinal shortening were both reduced in the septum (P < .01 at all levels). The principal strain associated with 3D maximal contraction was slightly depressed in many regions, significantly in the basal septum (-0.18 +/- 0.05 versus -0.22 +/- 0.02, P < .05) and anterior (-0.20 +/- 0.05 versus -0.23 +/- 0.02, P < .05) walls. In contrast, LV torsion (twist of the apex about the long axis relative to the base) was greater in HCM patients (19.9 +/- 2.4 degrees versus 14.6 +/- 2.7 degrees, P < .01). CONCLUSIONS: HCM patients had reduced 3D myocardial shortening on a regional basis; however, LV torsion was increased.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.
Zerhouni, E. A., Parish, D. M., Rogers, W. J., Yang, A., & Shapiro, E. P. (1988) · Radiology · doi:10.1148/radiology.169.1.3420283 · Cited by 1,430
Maron, B. J., Bonow, R. O., Cannon, R. O., Leon, M. B., & Epstein, S. E. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703263161305 · Cited by 896
Mathematical model of geometry and fibrous structure of the heart
Nielsen, P. M., Le Grice, I. J., Smaill, B. H., & Hunter, P. J. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.260.4.h1365 · Cited by 657
Passive Material Properties of Intact Ventricular Myocardium Determined From a Cylindrical Model
Guccione, J. M., McCulloch, A. D., & Waldman, L. K. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2894084 · Cited by 623
Maron, B. J., Gottdiener, J. S., & Epstein, S. E. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90068-0 · Cited by 607
A First Course in Continuum Mechanics
Gonzalez, O., & Stuart, A. M. (2001) · Cambridge University Press eBooks · doi:10.1017/cbo9780511619571 · Cited by 601
Heart wall motion: improved method of spatial modulation of magnetization for MR imaging.
Axel, L., & Dougherty, L. (1989) · Radiology · doi:10.1148/radiology.172.2.2748813 · Cited by 597
Self-citationMaron, B. J., Bonow, R. O., Cannon, R. O., Leon, M. B., & Epstein, S. E. (1987) · New England Journal of Medicine · doi:10.1056/nejm198704023161405 · Cited by 370
Waldman, L. K., Fung, Y. C., & Covell, J. W. (1985) · Circulation Research · doi:10.1161/01.res.57.1.152 · Cited by 363
Cited by
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
Normal values for cardiovascular magnetic resonance in adults and children
Kawel-Boehm, N., Maceira, A., Valsangiacomo-Buechel, E. R., Vogel-Claussen, J., Turkbey, E. B., Williams, R., Plein, S., Tee, M., Eng, J., & Bluemke, D. A. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0111-7 · Cited by 746
How to diagnose diastolic heart failure
European Study Group on Diastolic H (1998) · European Heart Journal · doi:10.1053/euhj.1998.1057 · Cited by 615
Twist Mechanics of the Left Ventricle
Sengupta, P. P., Tajik, A. J., Chandrasekaran, K., & Khandheria, B. K. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2008.02.006 · Cited by 604
DENSE: Displacement Encoding with Stimulated Echoes in Cardiac Functional MRI
Aletras, A. H., Ding, S., Balaban, R. S., & Wen, H. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1676 · Cited by 526
Moore, C. C., Lugo-Olivieri, C. H., McVeigh, E. R., & Zerhouni, E. A. (2000) · Radiology · doi:10.1148/radiology.214.2.r00fe17453 · Cited by 421
Notomi, Y., Martin-Miklovic, M. G., Oryszak, S. J., Shiota, T., Deserranno, D., Popovic, Z. B., Garcia, M. J., Greenberg, N. L., & Thomas, J. D. (2006) · Circulation · doi:10.1161/circulationaha.105.596502 · Cited by 385
Hor, K. N., Gottliebson, W. M., Carson, C., Wash, E., Cnota, J., Fleck, R., Wansapura, J., Klimeczek, P., Al-Khalidi, H. R., Chung, E. S., et al. (2010) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2009.11.006 · Cited by 379
Laminar fiber architecture and three-dimensional systolic mechanics in canine ventricular myocardium
Costa, K. D., Takayama, Y., McCulloch, A. D., & Covell, J. W. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.2.h595 · Cited by 313
LeGrice, I. J., Takayama, Y., & Covell, J. W. (1995) · Circulation Research · doi:10.1161/01.res.77.1.182 · Cited by 314
Ibrahim, E.-S. H. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-36 · Cited by 274
Clinical Indications for Cardiovascular Magnetic Resonance (CMR): Consensus Panel Report #
Pennell, D., Sechtem, U., Higgins, C., Manning, W., Pohost, G., Rademakers, F., van Rossum, A., Shaw, L., & Kent Yucel, E. (2004) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-200038581 · Cited by 274
Davis, J. S., Hassanzadeh, S., Winitsky, S., Lin, H., Satorius, C., Vemuri, R., Aletras, A. H., Wen, H., & Epstein, N. D. (2001) · Cell · doi:10.1016/s0092-8674(01)00586-4 · Cited by 271
Assessment of Nonischemic Myocardial Fibrosis
Jellis, C., Martin, J., Narula, J., & Marwick, T. H. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.02.047 · Cited by 269
Three-dimensional analysis of regional cardiac function: a model of rabbit ventricular anatomy
Vetter, F. J., & McCulloch, A. D. (1998) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(98)00006-6 · Cited by 255
Popović, Z. B., Kwon, D. H., Mishra, M., Buakhamsri, A., Greenberg, N. L., Thamilarasan, M., Flamm, S. D., Thomas, J. D., Lever, H. M., & Desai, M. Y. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.09.011 · Cited by 252
Carruth, E. D., McCulloch, A. D., & Omens, J. H. (2016) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2016.11.004 · Cited by 38
“Difficulties include potentially low signal to noise ratio and the challenge of converting data from 2D tagged images to 3D displacements, which has been addressed in various ways (Azhari et al., 1993), (Chuang et al., 2010), (Ibrahim, 2011), (Young et al., 1994b), (Zhong et al., 2008).”
Background
Metadata
- Authors
- Young, A. A., Kramer, C. M., Ferrari, V. A., Axel, L., & Reichek, N.
- Venue
- Circulation
- Published
- 1994-08
- Volume
- 90
- Issue
- 2
- Pages
- 854-867
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2085356007
- Cited by
- 401
- References
- 27
- FWCI
- 6.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.