The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Endovascular Stent Design Dictates Experimental Restenosis and Thrombosis
Abstract
Background Vascular interventions that maximize initial lumen diameter provoke extensive neointimal hyperplasia but minimize its effects, causing long-term lumen size to be greater. Nevertheless, interventions such as endovascular stents, which increase lumen size above that achieved with balloon angioplasty, are subject to frequent thrombosis and restenosis. It has been unclear whether the response to stent-induced injury is determined solely by the degree of stent-induced arterial expansion or whether the geometric configuration of the stent or the material left in contact with the vessel wall also contribute. Methods and Results We examined the vascular response to steel stents deployed in denuded rabbit iliac arteries for 14 days. In one set of experiments, the effects of stent configuration were examined, holding diameter, mass, surface area, and stent surface material constant. In another set, stent surface material was changed, with mass, configuration, and diameter unaltered. Changing stent configuration to reduce strut-strut intersections by 29% without affecting mass or surface area reduced vascular injury by 42%, thrombosis by 69%, and neointimal hyperplasia by 38%. Monocyte adhesion to stented arteries correlated linearly with vascular trauma and neointimal hyperplasia ( r =.96, P <.01 for each). When the stainless steel surface was coated with an inert polymer material, vascular injury and neointimal hyperplasia were unchanged, but thrombosis was eliminated. Conclusions Surface material and geometric configuration of stents may be more important than postplacement diameter in determining neointimal hyperplasia and thrombosis. Alterations in configuration affect vascular injury and neointimal hyperplasia, while surface material plays a greater role in thrombosis. Monocytes may be important modulators of stent-induced intimal thickening. Clinical confirmation of these findings may alter coronary stent deployment techniques and future stent designs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
Schwartz, R. S., Huber, K. C., Murphy, J. G., Edwards, W. D., Camrud, A. R., Vlietstra, R. E., & Holmes, D. R. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90476-4 · Cited by 1,175
Inhibitors of Angiotensin-Converting Enzyme Prevent Myointimal Proliferation After Vascular Injury
Powell, J. S., Clozel, J.-P., Müller, R. K. M., Kuhn, H., Hefti, F., Hosang, M., & Baumgartner, H. R. (1989) · Science · doi:10.1126/science.2526370 · Cited by 1,052
Suppression by heparin of smooth muscle cell proliferation in injured arteries
CLOWES, A. W., & KARNOWSKY, M. J. (1977) · Nature · doi:10.1038/265625a0 · Cited by 790
Angiographic Follow-up after Placement of a Self-Expanding Coronary-Artery Stent
Serruys, P. W., Strauss, B. H., Beatt, K. J., Bertrand, M. E., Puel, J., Rickards, A. F., Meier, B., Goy, J.-J., Vogt, P., Kappenberger, L., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199101033240103 · Cited by 732
Schwartz, L., Bourassa, M. G., Lespérance, J., Aldridge, H. E., Kazim, F., Salvatori, V. A., Henderson, M., Bonan, R., & David, P. R. (1988) · New England Journal of Medicine · doi:10.1056/nejm198806303182603 · Cited by 692
(1992) · Circulation · doi:10.1161/01.cir.86.1.100 · Cited by 539
Dehmer, G. J., Popma, J. J., van den Berg, E. K., Eichhorn, E. J., Prewitt, J. B., Campbell, W. B., Jennings, L., Willerson, J. T., & Schmitz, J. M. (1988) · New England Journal of Medicine · doi:10.1056/nejm198809223191201 · Cited by 379
Cited by
Kastrati, A., Mehilli, J., Dirschinger, J., Dotzer, F., Schühlen, H., Neumann, F.-J., Fleckenstein, M., Pfafferott, C., Seyfarth, M., & Schömig, A. (2001) · Circulation · doi:10.1161/01.cir.103.23.2816 · Cited by 938
Pathology of Acute and Chronic Coronary Stenting in Humans
Farb, A., Sangiorgi, G., Carter, A. J., Walley, V. M., Edwards, W. D., Schwartz, R. S., & Virmani, R. (1999) · Circulation · doi:10.1161/01.cir.99.1.44 · Cited by 871
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Kornowski, R., Hong, M. K., Tio, F. O., Bramwell, O., Wu, H., & Leon, M. B. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00450-6 · Cited by 844
Kolandaivelu, K., Swaminathan, R., Gibson, W. J., Kolachalama, V. B., Nguyen-Ehrenreich, K.-L., Giddings, V. L., Coleman, L., Wong, G. K., & Edelman, E. R. (2011) · Circulation · doi:10.1161/circulationaha.110.003210 · Cited by 802
Self-citationYakacki, C. M., Shandas, R., Lanning, C., Rech, B., Eckstein, A., & Gall, K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.030 · Cited by 618
Morphological Predictors of Restenosis After Coronary Stenting in Humans
Farb, A., Weber, D. K., Kolodgie, F. D., Burke, A. P., & Virmani, R. (2002) · Circulation · doi:10.1161/01.cir.0000019071.72887.bd · Cited by 593
Pletcher, M. J., Tice, J. A., Pignone, M., & Browner, W. S. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.12.1285 · Cited by 567
Pache, J. Ü., Kastrati, A., Mehilli, J., Schühlen, H., Dotzer, F., Hausleiter, J. Ö., Fleckenstein, M., Neumann, F.-J., Sattelberger, U., Schmitt, C., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00119-0 · Cited by 557
Coronary in-stent restenosis: Current status and future strategies
Lowe, H. C., Oesterle, S. N., & Khachigian, L. M. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01742-9 · Cited by 414
Cardiovascular stent design and vessel stresses: a finite element analysis
Lally, C., Dolan, F., & Prendergast, P. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.07.022 · Cited by 410
Sarno, G., Lagerqvist, B., Fröbert, O., Nilsson, J., Olivecrona, G., Omerovic, E., Saleh, N., Venetzanos, D., & James, S. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr479 · Cited by 378
Role of Endothelial Shear Stress in Stent Restenosis and Thrombosis
Koskinas, K. C., Chatzizisis, Y. S., Antoniadis, A. P., & Giannoglou, G. D. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.10.903 · Cited by 347
Restenosis after coronary placement of various stent types
Kastrati, A., Mehilli, J., Dirschinger, J., Pache, J., Ulm, K., Schühlen, H., Seyfarth, M., Schmitt, C., Blasini, R., Neumann, F.-J., et al. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01268-6 · Cited by 324
Drachman, D. E., Edelman, E. R., Seifert, P., Groothuis, A. R., Bornstein, D. A., Kamath, K. R., Palasis, M., Yang, D., Nott, S. H., & Rogers, C. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01020-2 · Cited by 286
Self-citationZotarolimus-Eluting Versus Bare-Metal Stents in Uncertain Drug-Eluting Stent Candidates
Valgimigli, M., Patialiakas, A., Thury, A., McFadden, E., Colangelo, S., Campo, G., Tebaldi, M., Ungi, I., Tondi, S., Roffi, M., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.11.053 · Cited by 280
In Vitro Analyses of Diamond-like Carbon Coated Stents
Gutensohn, K., Beythien, C., Bau, J., Fenner, T., Grewe, P., Koester, R., Padmanaban, K., & Kuehnl, P. (2000) · Thrombosis Research · doi:10.1016/s0049-3848(00)00295-4 · Cited by 279
Danenberg, H. D., Golomb, G., Groothuis, A., Gao, J., Epstein, H., Swaminathan, R. V., Seifert, P., & Edelman, E. R. (2003) · Circulation · doi:10.1161/01.cir.0000097002.69209.cd · Cited by 104
Self-citation
Metadata
- Authors
- Rogers, C., & Edelman, E. R.
- Venue
- Circulation
- Published
- 1995-06-15
- Volume
- 91
- Issue
- 12
- Pages
- 2995-3001
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1976855765
- Cited by
- 543
- References
- 22
- FWCI
- 21.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.