CoChat

Relation Between Diastolic Perfusion Time and Coronary Artery Stenosis During Stress-Induced Myocardial Ischemia

Ferro, Giuseppe, Duilio, Carlo, Spinelli, Letizia, Liucci, Giovanni Antonio, Mazza, Felice, Indolfi, Ciro · 1995 · Circulation
Cited by 118

The DOI matches its Crossref record.

Abstract

Background Experimental studies have demonstrated that during stress-induced myocardial ischemia, coronary obstruction and diastolic perfusion time are factors that limit subendocardial perfusion and correlate to degree of myocardial dysfunction. The relation between these two factors has not yet been investigated in humans. The aim of the present study was to assess the relation between diastolic perfusion time and degree of coronary stenosis during different types of stress tests. Methods and Results Nine patients with isolated and proximal stenosis of the left anterior descending coronary artery were selected. Patients underwent three different randomized stress tests (upright, supine bicycle stress test, and transesophageal atrial pacing). Diastolic perfusion time, heart rate (RR interval), and systolic and diastolic pressures were measured during the test and at the ischemic threshold (0.1-mV ST-segment depression). Angiographic measurements of coronary stenosis were evaluated by quantitative coronary angiography. At the ischemic threshold, significant differences among tests were found in heart rate (P<.05), systolic pressure (P<.001), and diastolic pressure (P<.05). In each stress test, diastolic perfusion time at the ischemic threshold was closely correlated with minimal stenosis diameter (r=.97;P<.001) and percent diameter stenosis (r=.92;P<.001) with no difference among the tests. In contrast, heart rate, rate-pressure product, and time to ischemic threshold were not significantly correlated with percent diameter stenosis and minimal stenosis diameter. No significant correlation was observed at the ischemic threshold between diastolic perfusion time and corresponding values of heart rate, despite the close correlation at rest (r=.95;P<.001). Conclusions Despite differences in associated hemodynamic responses to various stress tests, a close relation exists between stenosis severity and diastolic perfusion time at the onset of stress-induced myocardial ischemia. Therefore, diastolic perfusion time at the ischemic threshold may be an indirect estimate of the hemodynamic significance of coronary stenosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.92.3.342

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 118

Metadata

Authors
Ferro, G., Duilio, C., Spinelli, L., Liucci, G. A., Mazza, F., & Indolfi, C.
Venue
Circulation
Published
1995-08
Volume
92
Issue
3
Pages
342-347
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1993700883
Cited by
118
References
0
FWCI
1.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Relation Between Diastolic Perfusion Time and Coronary Artery Stenosis During Stress-Induced Myocardial Ischemia. https://app.cochat.ai/papers/10.1161/01.cir.92.3.342
The paper
Ferro, G., Duilio, C., Spinelli, L., Liucci, G. A., Mazza, F., & Indolfi, C. (1995). Relation Between Diastolic Perfusion Time and Coronary Artery Stenosis During Stress-Induced Myocardial Ischemia. Circulation. https://doi.org/10.1161/01.cir.92.3.342

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.