Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 166

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Pressure-Diameter Relation of the Human Aorta: A New Method of Determination by the Application of a Special Ultrasonic Dimension Catheter

Stefanadis, Christodoulos, Stratos, Costas, Vlachopoulos, Charalambos, Marakas, Stelios, Boudoulas, Harisios, Kallikazaros, Ioannis, Tsiamis, Eleftherios, Toutouzas, Konstantinos, Sioros, Lambros, Toutouzas, Pavlos·1995·Circulation

Abstract

Background Pressure-diameter relation of the aorta provides important information about the elastic properties of the vessel. However, owing to methodological limitations, data regarding this relation are limited in conscious humans. In the present study, we assessed a new method for the direct estimation of the elastic properties of the aorta in conscious humans by simultaneous acquisition of instantaneous aortic pressure and diameter. Methods and Results With this method, instantaneous diameter of the thoracic aorta was acquired by a newly designed intravascular catheter developed in our institution that incorporates an ultrasonic displacement meter at its distal end. Instantaneous aortic pressure was acquired simultaneously at the same aortic level with a catheter-tip micromanometer. Aortic pressure-diameter loops were derived from computer analysis of data. After in vitro and animal testing, elastic properties of the aorta were investigated in coronary artery disease (CAD) patients (n=15) and compared with those of control subjects (n=10). Aortic distensibility was less in the CAD group than in the control group (1.73±0.33 versus 3.95±1.09×10 −6 ×cm 2 ×dyne −1 , P <.001). Compared with control subjects, the mean value of the slope of the pressure-diameter loops was significantly greater in the CAD group (38.89±8.75 versus 19.62±5.46 mm Hg · mm −1 , P <.001), whereas the mean value of the intercept was lower in this latter group of patients (−785.60±177.55 versus −313.43±126.41 mm Hg, P <.001). An excellent correlation was found between the slope of pressure-diameter loop and age in the group of control subjects ( r =.827). Ninety-three percent of the patients with CAD had values above the upper 95% confidence limits of the control subjects ( P <.001). In a third group of patients (n=16) in whom assessment of pulse wave velocity was also included in the study of the elastic properties of the aorta, pulse wave velocity had a strong inverse correlation with aortic distensibility ( r =−.95) and a strong positive correlation with the slope of the pressure-diameter loop ( r =.97). Conclusions This new method of determination of pressure-diameter of the aorta enables an accurate and reliable evaluation of the elastic properties of the aorta in conscious humans and may be useful for a profound study of human aorta mechanics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.92.8.2210

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 166

Metadata

Authors
Stefanadis, C., Stratos, C., Vlachopoulos, C., Marakas, S., Boudoulas, H., Kallikazaros, I., Tsiamis, E., Toutouzas, K., Sioros, L., & Toutouzas, P.
Venue
Circulation
Published
1995-10-15
Volume
92
Issue
8
Pages
2210-2219
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1978059873
Cited by
166
References
3
FWCI
2.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pressure-Diameter Relation of the Human Aorta: A New Method of Determination by the Application of a Special Ultrasonic Dimension Catheter. https://app.cochat.ai/papers/10.1161/01.cir.92.8.2210
The paper
Stefanadis, C., Stratos, C., Vlachopoulos, C., Marakas, S., Boudoulas, H., Kallikazaros, I., Tsiamis, E., Toutouzas, K., Sioros, L., & Toutouzas, P. (1995). Pressure-Diameter Relation of the Human Aorta: A New Method of Determination by the Application of a Special Ultrasonic Dimension Catheter. Circulation. https://doi.org/10.1161/01.cir.92.8.2210

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.