Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 331

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Thermal Heterogeneity Within Human Atherosclerotic Coronary Arteries Detected In Vivo: A New Method of Detection by Application of a Special Thermography Catheter

Open access
Stefanadis, Christodoulos, Diamantopoulos, Leonidas, Vlachopoulos, Charalambos, Tsiamis, Eleftherios, Dernellis, John, Toutouzas, Konstantinos, Stefanadi, Elli, Toutouzas, Pavlos·1999·Circulation

Abstract

Background —Activated macrophages play an important role in the pathogenesis of acute ischemic syndromes. It has been postulated that detection of heat released by activated inflammatory cells of atherosclerotic plaques may predict plaque rupture and thrombosis. Previous ex vivo studies have shown that there is thermal heterogeneity in human carotid atherosclerotic plaques. Methods and Results —To measure the temperature of human arteries in vivo, we developed a catheter-based technique. Ninety patients (45 with normal coronary arteries, 15 with stable angina [SA], 15 with unstable angina [UA], and 15 with acute myocardial infarction [AMI]) were studied. The thermistor of the thermography catheter has a temperature accuracy of 0.05°C, a time constant of 300 ms, and a spatial resolution of 0.5 mm. Temperature was constant within the arteries of the control subjects, whereas most atherosclerotic plaques showed higher temperature compared with healthy vessel wall. Temperature differences between atherosclerotic plaque and healthy vessel wall increased progressively from SA to AMI patients (difference of plaque temperature from background temperature, 0.106±0.110°C in SA, 0.683±0.347°C in UA, and 1.472±0.691°C in AMI). Heterogeneity within the plaque was shown in 20%, 40%, and 67% of the patients with SA, UA, and AMI, respectively, whereas no heterogeneity was shown in the control subjects. Conclusions —Thermal heterogeneity within human atherosclerotic coronary arteries was shown in vivo by use of a special thermography catheter. This heterogeneity is larger in UA and AMI, suggesting that it may be related to the pathogenesis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.99.15.1965

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 331

Metadata

Authors
Stefanadis, C., Diamantopoulos, L., Vlachopoulos, C., Tsiamis, E., Dernellis, J., Toutouzas, K., Stefanadi, E., & Toutouzas, P.
Venue
Circulation
Published
1999-04-20
Volume
99
Issue
15
Pages
1965-1971
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2083336004
Cited by
331
References
15
FWCI
20.97
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Thermal Heterogeneity Within Human Atherosclerotic Coronary Arteries Detected In Vivo: A New Method of Detection by Application of a Special Thermography Catheter. https://app.cochat.ai/papers/10.1161/01.cir.99.15.1965
The paper
Stefanadis, C., Diamantopoulos, L., Vlachopoulos, C., Tsiamis, E., Dernellis, J., Toutouzas, K., Stefanadi, E., & Toutouzas, P. (1999). Thermal Heterogeneity Within Human Atherosclerotic Coronary Arteries Detected In Vivo: A New Method of Detection by Application of a Special Thermography Catheter. Circulation. https://doi.org/10.1161/01.cir.99.15.1965

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.