Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 175

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Effect of the Implantable Left Ventricular Assist Device on Neuroendocrine Activation in Heart Failure

James, Karen B., McCarthy, Patrick M., Thomas, James D., Vargo, Rita, Hobbs, Robert E., Sapp, Shelly, Bravo, Emmanuel · 1995 · Circulation

Abstract

Background The HeartMate left ventricular assist device has been successfully used as a bridge to cardiac transplantation. Because many patients exhibit marked clinical improvement in their heart failure after HeartMate implantation, we studied the physiological effect of this device on the neurohormonal axis. Methods and Results In 13 patients awaiting transplant (mean cardiac index, 1.7±0.3 L · min −1 · m −2 ) who underwent HeartMate implantation, venous atrial natriuretic peptide, epinephrine, norepinephrine, plasma renin activity, angiotensin, and arginine vasopressin were measured immediately before insertion and at explant/transplantation. Mean time to explant was 86±40 days. All patients were taken off inotropic medications within 1 month. Mean cardiac index on support before explant was 3.1±0.9 L · min −1 · m −2 . Plasma renin activity decreased from 57±56 ng · mL −1 · h −1 at baseline (before insertion) to 3±3 ng · mL −1 · h −1 at explant (mean percent change, 92%; P <.001). Angiotensin II level decreased from 237±398 U/L at baseline to 14±14 U/L at explant (mean percent change, 73%; P <.001). Plasma epinephrine level fell from 6800±1323 pg/mL at baseline to 46±46 pg/mL at explant (mean percent change, 86%; P <.001). Norepinephrine level decreased from 2953±1457 pg/mL at baseline to 518±290 pg/mL at explant (mean percent change, 79%; P <.001). Atrial natriuretic peptide fell from baseline values of 227±196 to 168±40 pg/mL at explant (mean percent change, −49%; P =.519); and arginine vasopressin level decreased from 6±6 pg/mL at baseline to 0.8±0.5 pg/mL (mean percent change, 69%; P =.002). Conclusions We provide data supporting that the neurohormonal axis markedly improves after HeartMate implantation, providing biochemical confirmation of the improvement in hemodynamic status.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.92.9.191

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 175

Metadata

Authors
James, K. B., McCarthy, P. M., Thomas, J. D., Vargo, R., Hobbs, R. E., Sapp, S., & Bravo, E.
Venue
Circulation
Published
1995-11
Volume
92
Issue
9
Pages
191-195
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2129492017
Cited by
175
References
1
FWCI
4.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of the Implantable Left Ventricular Assist Device on Neuroendocrine Activation in Heart Failure. https://app.cochat.ai/papers/10.1161/01.cir.92.9.191
The paper
James, K. B., McCarthy, P. M., Thomas, J. D., Vargo, R., Hobbs, R. E., Sapp, S., & Bravo, E. (1995). Effect of the Implantable Left Ventricular Assist Device on Neuroendocrine Activation in Heart Failure. Circulation. https://doi.org/10.1161/01.cir.92.9.191

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.