Noninvasive Quantification of Myocardial Blood Flow in Humans: A Direct Comparison of the [13N]Ammonia and the [15O]Water Techniques
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background[13 N]Ammonia has been validated in dog studies as a myocardial blood flow tracer. Estimates of myocardial blood flow by [13 N]ammonia were highly linearly correlated to those by the microsphere and blood sample techniques. However, estimates of myocardial blood flow with [13 N]ammonia in humans have not yet been compared with those by an independent technique. This study therefore tested the hypothesis that the [13 N]ammonia positron emission tomographic technique in humans gives estimates of myocardial blood flow comparable to those obtained with the [15 O]water technique. Methods and Results A total of 30 pairs of positron emission tomographic flow measurements were performed in 30 healthy volunteers; 15 volunteers were studied at rest and 15 during adenosine-induced hyperemia. Estimates of average and of regional myocardial blood flow by the [13 N]ammonia and the [15 O]water approaches correlated well (y=0.02+1.02 x,r=.99,P<.001, SEE=0.023 for average and y=0.06+1.00 x,r=.97,P<.001, SEE=0.025 for regional values) over a flow range of 0.45 to 4.74 mL·min−1·g−1. At rest, mean myocardial blood flow was 0.64±0.09 mL·min−1·g−1 for [13 N]ammonia and 0.66±0.12 mL·min−1·g−1 for [15 O]water (P=NS). For adenosine-induced hyperemia, mean myocardial blood flow was 2.63±0.75 mL·min−1·g−1 for [13 N]ammonia and 2.73±0.77 mL·min−1·g−1 for [15 O]water (P=NS). The coefficient of variation as an index of the observed heterogeneity of myocardial blood flow averaged, for [13 N]ammonia, 9±4% at rest and 12±7% during stress and, for [15 O]water, 14±11% at rest and 16±9% during stress. The coefficients of variation for [15 O]water were significantly higher than those for [13 N]ammonia (P=.004 at rest and P=.03 during stress). Conclusions The two approaches yield comparable estimates of myocardial blood flow in humans, which supports the validity of the [13 N]ammonia method in human myocardium previously shown only in animals. However, the [15 O]water approach reveals a greater heterogeneity (presumably method-related), which might limit the accuracy of sectorial myocardial blood flow estimates in humans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of probability as an aid in the clinical diagnosis of coronary artery disease.
Diamond, G. A., & Forrester, J. S. (1979) · New England Journal of Medicine · doi:10.1056/nejm197906143002402 · Cited by 2,664
Cited by
Schindler, T. H., Schelbert, H. R., Quercioli, A., & Dilsizian, V. (2010) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2010.04.007 · Cited by 424
Self-citationMurthy, V. L., Bateman, T. M., Beanlands, R. S., Berman, D. S., Borges-Neto, S., Chareonthaitawee, P., Cerqueira, M. D., deKemp, R. A., DePuey, E. G., Dilsizian, V., et al. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.201368 · Cited by 346
Danad, I., Uusitalo, V., Kero, T., Saraste, A., Raijmakers, P. G., Lammertsma, A. A., Heymans, M. W., Kajander, S. A., Pietilä, M., James, S., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.05.069 · Cited by 330
Skeletal Blood Flow in Bone Repair and Maintenance
Tomlinson, R. E., & Silva, M. J. (2013) · Bone Research · doi:10.4248/br201304002 · Cited by 296
Clinical Myocardial Perfusion PET/CT
Di Carli, M. F., Dorbala, S., Meserve, J., El Fakhri, G., Sitek, A., & Moore, S. C. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.032789 · Cited by 290
Metadata
- Authors
- Nitzsche, E. U., Choi, Y., Czernin, J., Hoh, C. K., Huang, S.-C., & Schelbert, H. R.
- Venue
- Circulation
- Published
- 1996-06
- Volume
- 93
- Issue
- 11
- Pages
- 2000-2006
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2065158527
- Cited by
- 157
- References
- 1
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Quantification of Myocardial Blood Flow in Humans: A Direct Comparison of the [13N]Ammonia and the [15O]Water Techniques. https://app.cochat.ai/papers/10.1161/01.cir.93.11.2000
- The paper
- Nitzsche, E. U., Choi, Y., Czernin, J., Hoh, C. K., Huang, S.-C., & Schelbert, H. R. (1996). Noninvasive Quantification of Myocardial Blood Flow in Humans: A Direct Comparison of the [13N]Ammonia and the [15O]Water Techniques. Circulation. https://doi.org/10.1161/01.cir.93.11.2000
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.