CoChat

Noninvasive Quantification of Myocardial Blood Flow in Humans: A Direct Comparison of the [13N]Ammonia and the [15O]Water Techniques

Nitzsche, Egbert U., Choi, Yong, Czernin, Johannes, Hoh, Carl K., Huang, Sung-Cheng, Schelbert, Heinrich R. · 1996 · Circulation
Cited by 157

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background[13 N]Ammonia has been validated in dog studies as a myocardial blood flow tracer. Estimates of myocardial blood flow by [13 N]ammonia were highly linearly correlated to those by the microsphere and blood sample techniques. However, estimates of myocardial blood flow with [13 N]ammonia in humans have not yet been compared with those by an independent technique. This study therefore tested the hypothesis that the [13 N]ammonia positron emission tomographic technique in humans gives estimates of myocardial blood flow comparable to those obtained with the [15 O]water technique. Methods and Results A total of 30 pairs of positron emission tomographic flow measurements were performed in 30 healthy volunteers; 15 volunteers were studied at rest and 15 during adenosine-induced hyperemia. Estimates of average and of regional myocardial blood flow by the [13 N]ammonia and the [15 O]water approaches correlated well (y=0.02+1.02 x,r=.99,P<.001, SEE=0.023 for average and y=0.06+1.00 x,r=.97,P<.001, SEE=0.025 for regional values) over a flow range of 0.45 to 4.74 mL·min−1·g−1. At rest, mean myocardial blood flow was 0.64±0.09 mL·min−1·g−1 for [13 N]ammonia and 0.66±0.12 mL·min−1·g−1 for [15 O]water (P=NS). For adenosine-induced hyperemia, mean myocardial blood flow was 2.63±0.75 mL·min−1·g−1 for [13 N]ammonia and 2.73±0.77 mL·min−1·g−1 for [15 O]water (P=NS). The coefficient of variation as an index of the observed heterogeneity of myocardial blood flow averaged, for [13 N]ammonia, 9±4% at rest and 12±7% during stress and, for [15 O]water, 14±11% at rest and 16±9% during stress. The coefficients of variation for [15 O]water were significantly higher than those for [13 N]ammonia (P=.004 at rest and P=.03 during stress). Conclusions The two approaches yield comparable estimates of myocardial blood flow in humans, which supports the validity of the [13 N]ammonia method in human myocardium previously shown only in animals. However, the [15 O]water approach reveals a greater heterogeneity (presumably method-related), which might limit the accuracy of sectorial myocardial blood flow estimates in humans.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.93.11.2000

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Nitzsche, E. U., Choi, Y., Czernin, J., Hoh, C. K., Huang, S.-C., & Schelbert, H. R.
Venue
Circulation
Published
1996-06
Volume
93
Issue
11
Pages
2000-2006
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2065158527
Cited by
157
References
1
FWCI
6.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.