Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Reduction in Thrombotic Events With Heparin-Coated Palmaz-Schatz Stents in Normal Porcine Coronary Arteries

Open access
Hårdhammar, Peter A., van Beusekom, Heleen M.M., Emanuelsson, Håkan U., Hofma, Sjoerd H., Albertsson, Per A., Verdouw, Pieter D., Boersma, Eric, Serruys, Patrick W., van der Giessen, Willem J.·1996·Circulation

Abstract

Background The use of stents improves the result after balloon coronary angioplasty. Thrombogenicity of stents is, however, a concern. In the present study, we compared stents with an antithrombotic coating with regular stents. Methods and Results Regular stents were placed in coronary arteries of pigs receiving no aspirin (group 1; n=8) or aspirin over 4 weeks (group 2, n=10) or 12 weeks (group 3, n=9). Stents coated with heparin (antithrombin III uptake, 5 pmol/stent) were placed in 7 pigs that did not receive aspirin (group 4). The other animals received aspirin and coated stents with a heparin activity of 12 pmol antithrombin III/stent (group 5, n=10) or 20 pmol/stent (group 6, n=10; group 7, n=10). Quantitative arteriography was performed at implantation and after 4 (groups 1, 2, and 4 through 6) or 12 weeks (groups 3 and 7). In an additional 5 animals, five regular and five coated stents (20 pmol/stent) were placed and explanted after 5 days for examination of the early responses to the implants. Thrombotic occlusion of the regular stent occurred in 9 of 27 in groups 1 through 3. However, in 0 of 30 of the animals receiving high-activity heparin-coated stents (groups 5 through 7), thrombotic stent occlusion was observed ( P <.001). Histological analysis at 4 weeks showed that the neointima in group 6 was thicker compared with its control group 2 (259±104 and 117±36 μm, P <.01), but at 12 weeks the thickness was similar (152±61 and 198±49 μm, respectively). Comparison at 5 days suggested delayed endothelialization of the coating. Conclusions High-activity heparin coating of stents eliminates subacute thrombosis in porcine coronary arteries.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.93.3.423

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 187

Metadata

Authors
Hårdhammar, P. A., van Beusekom, H. M. M., Emanuelsson, H. U., Hofma, S. H., Albertsson, P. A., Verdouw, P. D., Boersma, E., Serruys, P. W., & van der Giessen, W. J.
Venue
Circulation
Published
1996-02
Volume
93
Issue
3
Pages
423-430
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2074299379
Cited by
187
References
1
FWCI
22.09
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reduction in Thrombotic Events With Heparin-Coated Palmaz-Schatz Stents in Normal Porcine Coronary Arteries. https://app.cochat.ai/papers/10.1161/01.cir.93.3.423
The paper
Hårdhammar, P. A., van Beusekom, H. M. M., Emanuelsson, H. U., Hofma, S. H., Albertsson, P. A., Verdouw, P. D., Boersma, E., Serruys, P. W., & van der Giessen, W. J. (1996). Reduction in Thrombotic Events With Heparin-Coated Palmaz-Schatz Stents in Normal Porcine Coronary Arteries. Circulation. https://doi.org/10.1161/01.cir.93.3.423

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.