The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Sex and Test Verification Bias: Impact on the Diagnostic Value of Exercise Echocardiography
Abstract
Background The use of exercise echocardiography for the diagnosis of coronary artery disease (CAD) has been validated in pilot studies but is not documented in clinical practice and in women comparatively with men. The objectives of this study were to determine the effects of sex and of test verification bias on the diagnostic performance of exercise echocardiography. Methods and Results Three thousand six hundred seventy-nine consecutive patients (1714 women, 1965 men) who underwent an exercise echocardiographic study were studied; the observed sensitivity, specificity, and correct classification rate were calculated among 340 patients (244 men, 96 women) who underwent angiography; to study the effect of test verification bias, sensitivity and specificity were estimated for all patients who underwent exercise echocardiography including those not referred to angiography. In the angiographic group, the prevalence of CAD was 60% in women and 80% in men. The observed sensitivity and specificity of exercise echocardiography was 78% and 44% in men and 79% and 37% in women. After adjustment for test verification bias, the estimated sensitivity was lower in women (32% versus 42% in men), whereas specificity was similar in both sexes. The positive predictive value was lower in women (66%) compared with men (84%). Conclusions In clinical practice, test verification bias results in a lower observed specificity and a higher sensitivity of exercise echocardiography. In women, positive predictive value and adjusted sensitivity are lower compared with that in men.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Efron, B., & Tibshirani, R. (1986) · Statistical Science · doi:10.1214/ss/1177013815 · Cited by 6,033
Analysis of probability as an aid in the clinical diagnosis of coronary artery disease.
Diamond, G. A., & Forrester, J. S. (1979) · New England Journal of Medicine · doi:10.1056/nejm197906143002402 · Cited by 2,664
Differences in the use of procedures between women and men hospitalized for coronary heart disease
Ayanian, J. Z., & Epstein, A. M. (1991) · New England Journal of Medicine · doi:10.1056/nejm199107253250401 · Cited by 1,188
Assessment of diagnostic tests when disease verification is subject to selection bias
Begg, C. B., & Greenes, R. A. (1983) · Biometrics · doi:10.2307/2530820 · Cited by 708
Isles, C. G., Hole, D. J., Hawthorne, V. M., & Lever, A. F. (1992) · The Lancet · doi:10.1016/0140-6736(92)90599-x · Cited by 277
Cited by
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.013 · Cited by 1,555
ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography: summary article
Cheitlin, M. D., Armstrong, W. F., Aurigemma, G. P., Beller, G. A., Bierman, F. Z., Davis, J. L., Douglas, P. S., Faxon, D. P., Gillam, L. D., Kimball, T. R., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)01065-9 · Cited by 1,402
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318277d6a0 · Cited by 845
Sources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798
Metadata
- Authors
- Roger, V. L., Pellikka, P. A., Bell, M. R., Chow, C. W. H., Bailey, K. R., & Seward, J. B.
- Venue
- Circulation
- Published
- 1997-01-21
- Volume
- 95
- Issue
- 2
- Pages
- 405-410
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2057163274
- Cited by
- 194
- References
- 5
- FWCI
- 13.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sex and Test Verification Bias: Impact on the Diagnostic Value of Exercise Echocardiography. https://app.cochat.ai/papers/10.1161/01.cir.95.2.405
- The paper
- Roger, V. L., Pellikka, P. A., Bell, M. R., Chow, C. W. H., Bailey, K. R., & Seward, J. B. (1997). Sex and Test Verification Bias: Impact on the Diagnostic Value of Exercise Echocardiography. Circulation. https://doi.org/10.1161/01.cir.95.2.405
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.