CoChat

Aortic Function in Arterial Hypertension Determined by Pressure-Diameter Relation: Effects of Diltiazem

Stefanadis, Christodoulos, Dernellis, John, Vlachopoulos, Charalambos, Tsioufis, Costas, Tsiamis, Eleftherios, Toutouzas, Konstantinos, Pitsavos, Christos, Toutouzas, Pavlos · 1997 · Circulation
Cited by 136

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background Aortic elastic properties, important determinants of left ventricular function and coronary blood flow, are compromised in hypertension. The aim of this study was to determine aortic function in hypertensive patients and in normal subjects before and after administration of diltiazem, a calcium antagonist widely used in the treatment of essential hypertension. Methods and Results The aortic pressure-diameter relation was obtained before and after diltiazem administration in 15 hypertensives and 15 control normotensives. Instantaneous diameter of the thoracic aorta was acquired with a high-fidelity intravascular catheter developed in our institution and previously validated. Instantaneous aortic pressure was measured simultaneously and at the same aortic level with a catheter-tip micromanometer. Energy loss due to the viscosity of aortic wall was measured from the area of the loop. Aortic distensibility was calculated using the formula 2×(pulsatile change in aortic diameter)/([diastolic aortic diameter]×[aortic pulse pressure]). At baseline, aortic distensibility was lower and energy loss was greater in hypertensives than in normotensives (distensibility: 1.4±0.3 versus 3.5±0.7 cm 2 · dyne −1 · 10 −6 , respectively, P <.001; energy loss: 14.1±3.3 versus 8.2±2.2 mm · mm Hg, respectively, P <.001). After diltiazem administration, aortic distensibility was increased, whereas energy loss was decreased in both hypertensives (peak response: distensibility, 2.0±0.4 cm 2 · dyne −1 · 10 −6 , P <.001; energy loss, 9.3±1.6 mm · mm Hg, P <.001) and normotensives (peak response: distensibility, 5.2±0.5 cm 2 · dyne −1 · 10 −6 , P <.001; energy loss, 5.0±1.2 mm · mm Hg, P <.001). Conclusions Aortic elastic properties are compromised and energy loss due to aortic wall viscosity is increased in hypertensives compared with normotensives. Function of the aorta is improved in both hypertensive and normotensive subjects after the administration of diltiazem.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.96.6.1853

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 136

Metadata

Authors
Stefanadis, C., Dernellis, J., Vlachopoulos, C., Tsioufis, C., Tsiamis, E., Toutouzas, K., Pitsavos, C., & Toutouzas, P.
Venue
Circulation
Published
1997-09-16
Volume
96
Issue
6
Pages
1853-1858
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2094029606
Cited by
136
References
2
FWCI
3.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Aortic Function in Arterial Hypertension Determined by Pressure-Diameter Relation: Effects of Diltiazem. https://app.cochat.ai/papers/10.1161/01.cir.96.6.1853
The paper
Stefanadis, C., Dernellis, J., Vlachopoulos, C., Tsioufis, C., Tsiamis, E., Toutouzas, K., Pitsavos, C., & Toutouzas, P. (1997). Aortic Function in Arterial Hypertension Determined by Pressure-Diameter Relation: Effects of Diltiazem. Circulation. https://doi.org/10.1161/01.cir.96.6.1853

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.