Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 265

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Pulmonary Autograft Procedure for Aortic Valve Disease: Long-term Results of the Pioneer Series

Chambers, John C., Somerville, Jane, Stone, Susan, Ross, Donald N. · 1997 · Circulation

Abstract

Background Pulmonary autograft replacement of the diseased aortic valve has not been widely practiced due to concerns regarding late autograft competence and the consequences of creating pulmonary valve disease. To investigate this, the fate of the pioneering series of patients has been determined. Methods and Results The 131 hospital survivors of the pulmonary autograft operation at the National Heart Hospital from 1967 to 1984 were identified and their outcomes determined to 1994. Age at operation was 11 to 52 years, and 109 patients were male. Autograft implantation was orthotopic subcoronary (107), free-standing root (20), or Dacron mounted (2). In 113 patients, homografts replaced the native pulmonary valve. Ten and 20 years after operation, survival was 85% and 61%, freedom from autograft replacement was 88% and 75%, and freedom from replacement of pulmonary position homografts was 89% and 80%, respectively. Causes of deaths (53) included chronic heart failure (13), complications of reoperation (12), and endocarditis (7). Autograft regurgitation, the most common indication for reoperation, appeared primarily technical in nature, usually due to cusp prolapse. Degeneration was found in only 3 of 30 explanted autografts, and the young patients showed no increase in late valve failure. Homografts outperformed other valve replacements in the pulmonary position, but patients with orthotopic subcoronary and root autografts survived similarly. Conclusions The pulmonary autograft offers low rates of degeneration, endocarditis, and thromboembolism for a period lasting >20 years, particularly in the young, with reoperation mainly required for malpositioning of the autograft cusps. The capacity of the autograft to maintain viability with minimal degeneration is not matched by any other biological valve replacement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.96.7.2206

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 265

Metadata

Authors
Chambers, J. C., Somerville, J., Stone, S., & Ross, D. N.
Venue
Circulation
Published
1997-10-07
Volume
96
Issue
7
Pages
2206-2214
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1981375818
Cited by
265
References
10
FWCI
9.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulmonary Autograft Procedure for Aortic Valve Disease: Long-term Results of the Pioneer Series. https://app.cochat.ai/papers/10.1161/01.cir.96.7.2206
The paper
Chambers, J. C., Somerville, J., Stone, S., & Ross, D. N. (1997). Pulmonary Autograft Procedure for Aortic Valve Disease: Long-term Results of the Pioneer Series. Circulation. https://doi.org/10.1161/01.cir.96.7.2206

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.