CoChat
Cited by 596

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Doppler Estimation of Left Ventricular Filling Pressure in Sinus Tachycardia: A New Application of Tissue Doppler Imaging

Open access
Nagueh, Sherif F., Mikati, Issam, Kopelen, Helen A., Middleton, Katherine J., Quiñones, Miguel A., Zoghbi, William A. · 1998 · Circulation

Abstract

Background —Doppler echocardiography is frequently used to predict filling pressures in normal sinus rhythm, but it is unknown whether it can be applied in sinus tachycardia, with merging of E and A velocities. Tissue Doppler imaging (TDI) can record the mitral annular velocity. The early diastolic velocity (E a ) behaves as a relative load-independent index of left ventricular relaxation, which corrects the influence of relaxation on the transmitral E velocity. Methods and Results —We evaluated 100 patients 64±12 years old with simultaneous Doppler and invasive hemodynamics. Mitral inflow was classified into 3 patterns: complete merging of E and A velocities (pattern A), discernible velocities with A dominance (B), or E dominance (C). The Doppler data were analyzed at the mitral valve tips for E, acceleration and deceleration times of E, and isovolumic relaxation time. In patterns B and C, the A velocity, E/A ratio, and atrial filling fraction were derived. Pulmonary venous flow velocities were also measured, and TDI was used to acquire E a and A a . Weak significant relations were observed between pulmonary capillary wedge pressure (PCWP) and sole parameters of mitral flow, pulmonary venous flow, and annular measurements. These were better for patterns A and C. E/E a ratio had the strongest relation to PCWP [ r =0.86, PCWP=1.55+1.47(E/E a )], irrespective of the pattern and ejection fraction. This equation was tested prospectively in 20 patients with sinus tachycardia. A strong relation was observed between catheter and Doppler PCWP ( r =0.91), with a mean difference of 0.4±2.8 mm Hg. Conclusions —The ratio of transmitral E velocity to E a can be used to estimate PCWP with reasonable accuracy in sinus tachycardia, even with complete merging of E and A velocities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.98.16.1644

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 596

Metadata

Authors
Nagueh, S. F., Mikati, I., Kopelen, H. A., Middleton, K. J., Quiñones, M. A., & Zoghbi, W. A.
Venue
Circulation
Published
1998-10-20
Volume
98
Issue
16
Pages
1644-1650
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2040519959
Cited by
596
References
21
FWCI
5.69
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.