Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 399

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Cardiac Improvement During Mechanical Circulatory Support: A Prospective Multicenter Study of the LVAD Working Group

Maybaum, Simon, Mancini, Donna, Xydas, Steve, Starling, Randall C., Aaronson, Keith, Pagani, Francis D., Miller, Leslie W., Margulies, Kenneth, McRee, Susan, Frazier, O.H., Torre-Amione, Guillermo·2007·Circulation

Abstract

Background— Myocardial recovery after left ventricular assist device (LVAD) support has been reported. The LVAD Working Group Recovery Study was a prospective multicenter trial to assess the incidence of myocardial recovery in patients bridged to cardiac transplantation. Methods and Results— After LVAD implantation, patients were evaluated with the use of rest echocardiograms with partial LVAD support and cardiopulmonary exercise testing. Dobutamine echocardiography with hemodynamic measurements was performed in those patients with left ventricular ejection fraction >40% during resting studies. Histological analysis was performed on myocardial samples taken at LVAD implantation and explantation. Sixty-seven LVAD patients with heart failure participated in the study. After 30 days, significant improvement occurred in left ventricular ejection fraction (17±7% versus 34±12%; P <0.001) and reductions in left ventricular end-diastolic diameter (7.1±1.2 versus 5.1±1.1 cm; P <0.001) and left ventricular mass (320±113 versus 194±79 g; P <0.001) compared with before LVAD. Thirty-four percent of patients had left ventricular ejection fraction >40% with partial device support. Left ventricular ejection fraction decreased over time to pre-LVAD measurement by 120 days. Peak V̇ o 2 improved with mechanical support (13.7±4.2 versus 18.9±5.5 mL/kg per minute, 30 versus 120 days; P <0.001). Tissue analysis revealed significant reductions in myocyte size, collagen content, and cardiac tumor necrosis factor-α. Six subjects (9%) underwent LVAD explantation for recovery. Conclusions— Cardiac function improves significantly after device implantation. Although cellular recovery and improvement in ventricular function are observed, the degree of clinical recovery is insufficient for device explantation in most patients with chronic heart failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.106.633180

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 399

Metadata

Authors
Maybaum, S., Mancini, D., Xydas, S., Starling, R. C., Aaronson, K., Pagani, F. D., Miller, L. W., Margulies, K., McRee, S., Frazier, O. H., & Torre-Amione, G.
Venue
Circulation
Published
2007-05-15
Volume
115
Issue
19
Pages
2497-2505
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2037859830
Cited by
399
References
17
FWCI
20.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac Improvement During Mechanical Circulatory Support: A Prospective Multicenter Study of the LVAD Working Group. https://app.cochat.ai/papers/10.1161/circulationaha.106.633180
The paper
Maybaum, S., Mancini, D., Xydas, S., Starling, R. C., Aaronson, K., Pagani, F. D., Miller, L. W., Margulies, K., McRee, S., Frazier, O. H., & Torre-Amione, G. (2007). Cardiac Improvement During Mechanical Circulatory Support: A Prospective Multicenter Study of the LVAD Working Group. Circulation. https://doi.org/10.1161/circulationaha.106.633180

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.