Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 363

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Asynchronous Electrical Activation Induces Asymmetrical Hypertrophy of the Left Ventricular Wall

Open access
van Oosterhout, Matthijs F. M., Prinzen, Frits W., Arts, Theo, Schreuder, Jan J., Vanagt, Ward Y. R., Cleutjens, Jack P. M., Reneman, Robert S.·1998·Circulation

Abstract

Background —Asynchronous electrical activation, induced by ventricular pacing, causes regional differences in workload, which is lower in early- than in late-activated regions. Because the myocardium usually adapts its mass and structure to altered workload, we investigated whether ventricular pacing leads to inhomogeneous hypertrophy and whether such adaptation, if any, affects global left ventricular (LV) pump function. Methods and Results —Eight dogs were paced at physiological heart rate for 6 months (AV sequential, AV interval 25 ms, ventricular electrode at the base of the LV free wall). Five dogs were sham operated and served as controls. Ventricular pacing increased QRS duration from 47.2±10.6 to 113±16.5 ms acutely and to 133.8±25.2 ms after 6 months. Two-dimensional echocardiographic measurements showed that LV cavity and wall volume increased significantly by 27±15% and 15±17%, respectively. The early-activated LV free wall became significantly (17±17%) thinner, whereas the late-activated septum thickened significantly (23±12%). Calculated sector volume did not change in the LV free wall but increased significantly in the septum by 39±13%. In paced animals, cardiomyocyte diameter was significantly (18±7%) larger in septum than in LV free wall, whereas myocardial collagen fraction was unchanged in both areas. LV pressure-volume analysis showed that ventricular pacing reduced LV function to a similar extent after 15 minutes and 6 months of pacing. Conclusions —Asynchronous activation induces asymmetrical hypertrophy and LV dilatation. Cardiac pump function is not affected by the adaptational processes. These data indicate that local cardiac load regulates local cardiac mass of both myocytes and collagen.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.98.6.588

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 363

Metadata

Authors
van Oosterhout, M. F. M., Prinzen, F. W., Arts, T., Schreuder, J. J., Vanagt, W. Y. R., Cleutjens, J. P. M., & Reneman, R. S.
Venue
Circulation
Published
1998-08-11
Volume
98
Issue
6
Pages
588-595
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1989871157
Cited by
363
References
21
FWCI
3.46
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Asynchronous Electrical Activation Induces Asymmetrical Hypertrophy of the Left Ventricular Wall. https://app.cochat.ai/papers/10.1161/01.cir.98.6.588
The paper
van Oosterhout, M. F. M., Prinzen, F. W., Arts, T., Schreuder, J. J., Vanagt, W. Y. R., Cleutjens, J. P. M., & Reneman, R. S. (1998). Asynchronous Electrical Activation Induces Asymmetrical Hypertrophy of the Left Ventricular Wall. Circulation. https://doi.org/10.1161/01.cir.98.6.588

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.