Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 167

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Left Ventricular Mass: Reliability of M-Mode and 2-Dimensional Echocardiographic Formulas

Myerson, Saul G., Montgomery, Hugh E., World, Michael J., Pennell, Dudley J. · 2002 · Hypertension

Abstract

The study of left ventricular (LV) hypertrophy is hindered by problems with LV mass measurement by echocardiography. Both the M-mode and 2D area-length formulas for calculating LV mass assume a fixed geometric shape, which may be a source of error. We examined this hypothesis by using cardiovascular magnetic resonance images to eliminate the confounding effects of acoustic access and image quality. LV mass was measured directly in 212 healthy subjects by means of a standard 3D cardiovascular magnetic resonance technique. LV mass was also calculated by using the cube-function and area-length formulas with measurements from the magnetic resonance images. A comparison of serial measurements was made by examining the changes in LV mass by all 3 techniques in those completing an exercise program (n=140). The cube-function technique showed a consistent underestimation of LV mass of 14.3 g, and there were wide 95% limits of agreement (±57.6 g and ±46.3 g for cube-function and area-length techniques, respectively) when compared with 3D measurement. There were similarly wide limits of agreement for the change in mass (±55.2 g and ±44.8 g for cube-function and area-length, respectively). The assumption of geometric shape in the cube-function and area-length formulas resulted in significant variation in LV mass estimates from direct measurement by using a 3D technique. The technique cannot be recommended either at a single time point or for serial studies in small populations; 3D imaging techniques, such as cardiovascular magnetic resonance, are preferable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.0000036401.99908.db

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 167

Metadata

Authors
Myerson, S. G., Montgomery, H. E., World, M. J., & Pennell, D. J.
Venue
Hypertension
Published
2002-11
Volume
40
Issue
5
Pages
673-678
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2160770910
Cited by
167
References
2
FWCI
7.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Left Ventricular Mass: Reliability of M-Mode and 2-Dimensional Echocardiographic Formulas. https://app.cochat.ai/papers/10.1161/01.hyp.0000036401.99908.db
The paper
Myerson, S. G., Montgomery, H. E., World, M. J., & Pennell, D. J. (2002). Left Ventricular Mass: Reliability of M-Mode and 2-Dimensional Echocardiographic Formulas. Hypertension. https://doi.org/10.1161/01.hyp.0000036401.99908.db

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.