Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 169

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Noninvasive Assessment of Local Pulse Pressure: Importance of Brachial-to-Radial Pressure Amplification

Verbeke, Francis, Segers, Patrick, Heireman, Steven, Vanholder, Raymond, Verdonck, Pascal, Van Bortel, Luc M. · 2005 · Hypertension

Abstract

The advocated SphygmoCor procedure uses a radial-to-aorta transfer function with calibration on brachial instead of radial artery pressure to assess the central pulse pressure. We compared these values with carotid artery pulse pressures obtained from a validated calibration method, assuming mean minus diastolic blood pressure constant throughout the large artery tree. From 44 healthy subjects (21 males; 22 to 68 years) pressure waves were obtained at the radial, brachial, and carotid artery with applanation tonometry. Using the calibration method, radial and carotid artery pressures were assessed from brachial artery waves and pressures. The effect of brachial-to-radial pulse pressure amplification, brachial pulse pressure, mean pressure, age, gender, height, body mass index, and smoking on differences between the 2 methods was assessed. Brachial artery pressure was 118±12/72±10 mm Hg. SphygmoCor central pulse pressure was 9.7±4.6 mm Hg lower ( P <0.001) than the carotid artery pulse pressure (33.0±6.8 versus 42.7±8.9 mm Hg). The difference between the 2 methods strongly depended ( P <0.001) on brachial-to-radial artery pulse pressure amplification (5.8±5.1 mm Hg; 12±11%) and less on brachial artery pulse pressure ( P =0.005). After calibration of the radial pressure wave with radial instead of brachial artery pressures, the difference between SphygmoCor central pulse pressure and carotid pulse pressure decreased with 4 mm Hg. The advocated SphygmoCor procedure systematically underestimates the central pulse pressure with brachial-to-radial pulse pressure amplification as important determinant. Therefore, calibration of radial artery pressure waves on brachial artery pressures should be avoided. The underestimation of central aortic pulse pressure caused by the radial-to-aorta transfer function itself is much less than previously reported.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.0000166723.07809.7e

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 169

Metadata

Authors
Verbeke, F., Segers, P., Heireman, S., Vanholder, R., Verdonck, P., & Van Bortel, L. M.
Venue
Hypertension
Published
2005-07
Volume
46
Issue
1
Pages
244-248
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2149293052
Cited by
169
References
5
FWCI
7.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Assessment of Local Pulse Pressure: Importance of Brachial-to-Radial Pressure Amplification. https://app.cochat.ai/papers/10.1161/01.hyp.0000166723.07809.7e
The paper
Verbeke, F., Segers, P., Heireman, S., Vanholder, R., Verdonck, P., & Van Bortel, L. M. (2005). Noninvasive Assessment of Local Pulse Pressure: Importance of Brachial-to-Radial Pressure Amplification. Hypertension. https://doi.org/10.1161/01.hyp.0000166723.07809.7e

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.