Sex Differences in Blood Pressure Response to Intermittent Hypoxia in Rats
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Intermittent hypoxia is used to mimic the arterial hypoxemia that occurs during sleep apnea. The present study examined the blood pressure and heart rate responses to exposure to intermittent hypoxia in male rats and in female rats before and after ovariectomy. Rats were instrumented with telemetry transmitters and blood pressure, heart rate, and activity measured during 7 days of exposure to intermittent hypoxia (3 minutes of normoxia [21% oxygen] alternating with 3 minutes 10% oxygen between 8 am and 4 pm , remainder of day at normoxia). Blood pressure increased in males, females, and ovariectomized females in response to 7 days of intermittent hypoxia during the hours of exposure to hypoxia. Blood pressure increased less in intact females (average change in blood pressure 1.6±0.6 mm Hg, n=11) than in females studied after ovariectomy (5.1±1.1 mm Hg, n=6) or males (5.4±1.0 mm Hg, n=10). This elevated blood pressure persisted throughout the remainder of the day when the animals were not exposed to intermittent hypoxia and remained significantly attenuated in female rats. Ovariectomy abolished the protection against the elevated blood pressure response to intermittent hypoxia in females. Heart rate increased only in males, and only during the period of the day associated with intermittent hypoxia. Female rats were protected against this tachycardia independent of the ovarian hormones. These results indicate that females are protected from the hypertensive and tachycardia effects of intermittent hypoxia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nieto, F. J. (2000) · JAMA · doi:10.1001/jama.283.14.1829 · Cited by 3,369
Sympathetic neural mechanisms in obstructive sleep apnea.
Somers, V. K., Dyken, M. E., Clary, M. P., & Abboud, F. M. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118235 · Cited by 2,527
Phillips, S. A., Olson, E. B., Morgan, B. J., & Lombard, J. H. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00683.2003 · Cited by 137
Cited by
Pathophysiology of Sleep Apnea
Dempsey, J. A., Veasey, S. C., Morgan, B. J., & O'Donnell, C. P. (2010) · Physiological Reviews · doi:10.1152/physrev.00043.2008 · Cited by 2,243
““Mild” CIH (10 events/h) caused a more modest increase in blood pressure in male rats and ovariectomized female rats and only a slight increase in intact females (244).”
BackgroundTherapeutic potential of intermittent hypoxia: a matter of dose
Navarrete-Opazo, A., & Mitchell, G. S. (2014) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00208.2014 · Cited by 469
Foster, G. E., Hanly, P. J., Ahmed, S. B., Beaudin, A. E., Pialoux, V., & Poulin, M. J. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.152108 · Cited by 177
Role of Carotid Body in Intermittent Hypoxia-Related Hypertension
Iturriaga, R., Oyarce, M. P., & Dias, A. C. R. (2017) · Current Hypertension Reports · doi:10.1007/s11906-017-0735-0 · Cited by 46
Breathing rate variability in obstructive sleep apnea during wakefulness
Pal, A., Martinez, F., Akey, M. A., Aysola, R. S., Henderson, L. A., Malhotra, A., & Macey, P. M. (2022) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.9728 · Cited by 21
Metadata
- Authors
- Hinojosa-Laborde, C., & Mifflin, S. W.
- Venue
- Hypertension
- Published
- 2005-10
- Volume
- 46
- Issue
- 4
- Pages
- 1016-1021
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2118176821
- Cited by
- 95
- References
- 3
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.