Effectiveness of Blood Pressure Control Outside the Medical Setting
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
We studied the effectiveness of blood pressure (BP) control outside the clinic by using ambulatory BP monitoring (ABPM) among a large number of hypertensive subjects treated in primary care centers across Spain. The sample consisted of 12 897 treated hypertensive subjects who had indications for ABPM. Office-based BP was calculated as the average of 2 readings. Twenty-four–hour ABPM was then performed using a SpaceLabs 90207 monitor under standardized conditions. A total of 3047 patients (23.6%) had their office BP controlled, and 6657 (51.6%) were controlled according to daytime ABPM. The proportion of office resistance or underestimation of patients’ BP control by physicians in the office (office BP ≥140/90 mm Hg and average daytime ambulatory BP <135/85 mm Hg) was 33.4%, and the proportion of isolated office control or overestimation of control (office BP <140/90 mm Hg and average daytime ambulatory BP ≥135/85 mm Hg) was 5.4%. BP control was more frequently underestimated in patients who were older, female, obese, or with morning BP determination than in their counterparts. BP control was more frequently overestimated in those who were younger, male, nonobese, smokers, or with evening BP determination. Ambulatory-based hypertension control was far better than office-based hypertension control. This conveys an encouraging message to clinicians, namely that they are actually doing better than is evidenced by office-based data. However, the burden of underestimation and overestimation of BP control at the office is still remarkable. Physicians should be aware that the likelihood of misestimating BP control is higher in some hypertensive subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chobanian, A. V., Bakris, G. L., Black, H. R., Cushman, W. C., Green, L. A., Izzo, J. L., Jones, D. W., Materson, B. J., Oparil, S., Wright, J. T., et al. (2003) · Hypertension · doi:10.1161/01.hyp.0000107251.49515.c2 · Cited by 13,271
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
PIERDOMENICO, S., LAPENNA, D., BUCCI, A., DITOMMASO, R., DIMASCIO, R., MANENTE, B., CALDARELLA, M., NERI, M., CUCCURULLO, F., & MEZZETTI, A. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.05.014 · Cited by 409
Impact of Obesity on 24-Hour Ambulatory Blood Pressure and Hypertension
Kotsis, V., Stabouli, S., Bouldin, M., Low, A., Toumanidis, S., & Zakopoulos, N. (2005) · Hypertension · doi:10.1161/01.hyp.0000158261.86674.8e · Cited by 262
Cited by
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationde la Sierra, A., Segura, J., Banegas, J. R., Gorostidi, M., de la Cruz, J. J., Armario, P., Oliveras, A., & Ruilope, L. M. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.168948 · Cited by 809
Self-citationPrevalence and Factors Associated With Circadian Blood Pressure Patterns in Hypertensive Patients
de la Sierra, A., Redon, J., Banegas, J. R., Segura, J., Parati, G., Gorostidi, M., de la Cruz, J. J., Sobrino, J., Llisterri, J. L., Alonso, J., et al. (2009) · Hypertension · doi:10.1161/hypertensionaha.108.124008 · Cited by 379
Self-citationA fully integrated wearable ultrasound system to monitor deep tissues in moving subjects
Lin, M., Zhang, Z., Gao, X., Bian, Y., Wu, R. S., Park, G., Lou, Z., Zhang, Z., Xu, X., Chen, X., et al. (2024) · Nature Biotechnology · doi:10.1038/s41587-023-01800-0 · Cited by 364
High prevalence of masked uncontrolled hypertension in people with treated hypertension
Banegas, J. R., Ruilope, L. M., de la Sierra, A., de la Cruz, J. J., Gorostidi, M., Segura, J., Martell, N., Garcia-Puig, J., Deanfield, J., & Williams, B. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu016 · Cited by 223
Self-citation
Metadata
- Authors
- Banegas, J. R., Segura, J., Sobrino, J., Rodríguez-Artalejo, F., de la Sierra, A., de la Cruz, J. J., Gorostidi, M., Sarría, A., & Ruilope, L. M.
- Venue
- Hypertension
- Published
- 2007-01
- Volume
- 49
- Issue
- 1
- Pages
- 62-68
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2144797485
- Cited by
- 182
- References
- 5
- FWCI
- 11.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.