Mild hypovolemic stress alters autonomic modulation of heart rate.
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In response to changes in central venous volume, changes in vagal efferent cardiac outflow have been demonstrated in animals but not in humans. In this study, frequency domains analysis was used to quantify modulation of heart rate by respiration and blood pressure in normal human adults undergoing mild central hypovolemic stress induced by blood donation and postural change. In supine subjects, blood donation caused no change in mean heart rate, pulse pressure, or in the variance of heart rate or blood pressure. There were small decreases in mean and systolic blood pressure. A significant decrease in vagal modulation of heart rate was seen in the 0.12-0.5-Hz frequency band, as measured by the change in the relation of lung volume to heart rate in this frequency band (-4.49 beats per minute [pbm] per liter [1], p < 0.001). Comparison of supine and tilt positions revealed marked changes in heart rate and blood pressure means and variances consistent with more pronounced decreases in intracardiac filling pressures and unloading of the arterial baroreceptors. A further progressive decrease in the vagal modulation of heart rate by lung volume was observed in the 0.12-0.5-Hz band, with a near-linear response of magnitude of respiratory sinus arrhythmia over a range of estimated central venous volume. Transfer function analysis can detect changes in autonomic response to mild degrees of central hypovolemia, which are insufficient to cause changes in mean heart rate or heart rate variance. This represents evidence for modulation of heart rate control by cardiopulmonary baroreceptors. A near-linear relation between magnitude of respiratory sinus arrhythmia and central venous volume suggests that this may have clinical relevance in patient monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Respiratory sinus arrhythmia in humans: how breathing pattern modulates heart rate
Hirsch, J. A., & Bishop, B. (1981) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1981.241.4.h620 · Cited by 1,105 · cited 1×
“'(7) Change in position from supine to 60° tilt was estimated to cause a decrease in intravascular volume of 20% (approximately 2 units) over 10 minutes, secondary to pooling of blood in the dependent extremities and movement of plasma into the interstitium.(22)-(24) Data are presented as mean±SEM for each of the four…”
MethodHuman sinus arrhythmia as an index of vagal cardiac outflow.
Eckberg, D. L. (1983) · Journal of Applied Physiology · doi:10.1152/jappl.1983.54.4.961 · Cited by 633 · cited 1×
“quency domain and time domain analyses of this relation reported in prior studies.(24) Vagal HR control is characterized by significant transfer magnitude at both High and Low frequencies, with a peak magnitude of about 15 bpm/l at a frequency of 0.”
MethodRespiratory sinus arrhythmia: a frequency dependent phenomenon
Angelone, A., & Coulter, N. A. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.3.479 · Cited by 441 · cited 1×
“This technique has been simply but effectively used to study respiratory sinus arrhythmia by plotting the magnitude and phase relation of the HR response to a measured respiratory excursion over a number of discrete frequencies.(21)'(22) Use of a random interval breathing technique allows efficient collection of data…”
MethodJOHNSON, J. M., ROWELL, L. B., NIEDERBERGER, M., & EISMAN, M. M. (1974) · Circulation Research · doi:10.1161/01.res.34.4.515 · Cited by 340 · cited 1×
“However, because of the absence of a HR response in these cases, it has been suggested that there is no change in the autonomic efferent outflow to the heart.(2)-(3)”
BackgroundThe role of low pressure baroreceptors in reflex vasoconstrictor responses in man
Zoller, R. P., Mark, A. L., Abboud, F. M., Schmid, P. G., & Heistad, D. D. (1972) · Journal of Clinical Investigation · doi:10.1172/jci107121 · Cited by 321
Abboud, F. M., Eckberg, D. L., Johannsen, U. J., & Mark, A. L. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012612 · Cited by 241
Phase relationship between normal human respiration and baroreflex responsiveness.
Eckberg, D. L., Kifle, Y. T., & Roberts, V. L. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013338 · Cited by 233
Cited by
McGee, S. (1999) · JAMA · doi:10.1001/jama.281.11.1022 · Cited by 583
Complex systems and the technology of variability analysis
Seely, A. J., & Macklem, P. T. (2004) · Critical Care · doi:10.1186/cc2948 · Cited by 447
Age dependency of cardiovascular autonomic responses to head-up tilt in healthy subjects
Laitinen, T., Niskanen, L., Geelen, G., Länsimies, E., & Hartikainen, J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00444.2003 · Cited by 176
“as well as a decrease in cardiovagal baroreflex sensitivity (8, 17, 21, 25, 41, 55, 57).”
BackgroundAhmad, S., Tejuja, A., Newman, K. D., Zarychanski, R., & Seely, A. J. (2009) · Critical Care · doi:10.1186/cc8132 · Cited by 151
“ranging from hypovolaemia [25] to heart failure [26-28], from”
BackgroundPostural tachycardia syndrome: time frequency mapping
Novak, V., Novak, P., Opfer-Gehrking, T. L., & Low, P. A. (1996) · Journal of the Autonomic Nervous System · doi:10.1016/s0165-1838(96)00101-4 · Cited by 33
Metadata
- Authors
- Triedman, J. K., Cohen, R. J., & Saul, J. P.
- Venue
- Hypertension
- Published
- 1993-02
- Volume
- 21
- Issue
- 2
- Pages
- 236-247
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W1994134817
- Cited by
- 89
- References
- 7
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.