Different Effects of Fosinopril and Atenolol on Wave Reflections in Hypertensive Patients
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We conducted this study to compare the effects of fosinopril versus atenolol on peripheral blood pressure, central arterial wave reflection, and left ventricular mass in a group of patients with essential hypertension. We conducted a double-blind, randomized trial of fosinopril and atenolol in 79 hypertensive patients (52 men, 27 women; mean age, 45.8±8.5 years; range, 30 to 68 years). Carotid pressure waveforms were recorded noninvasively by applanation tonometry with a Millar micromanometer-tipped probe. The extent of wave reflection was estimated by the augmentation index defined as the ratio of the amplitude of pressure wave above its systolic shoulder to the pulse pressure. The augmentation index, left ventricular mass index by two-dimensional echocardiography, and 24-hour ambulatory blood pressures were determined before and after 8 weeks of daily treatment with fosinopril (10 to 20 mg) or atenolol (50 to 100 mg) with or without diuretics and compared with those values in 79 normotensive control subjects. After 8 weeks of treatment, both drugs lowered 24-hour ambulatory peripheral systolic and diastolic pressures into the normal range to a similar extent (fosinopril, −18/−13 mm Hg; atenolol, −23/−17 mm Hg, both P =NS). On the other hand, whereas the elevated augmentation index in hypertensive patients compared with normotensive subjects (16±11% versus 10±8%) was completely normalized by fosinopril (−9.3±9.8%, P ≤.002), it was lowered by atenolol (−4.8±8.9%, P <.002) but to a significantly smaller extent (fosinopril versus atenolol effect, P =.04). Neither drug affected the slightly elevated left ventricular mass index (fosinopril, 93±13 gm/m 2 ; atenolol, 98±20 gm/m 2 ) compared with normotensive subjects (86±13 gm/m 2 ). At the doses used, fosinopril and atenolol reduced peripheral blood pressure similarly but had different effects on central systolic wave reflections, implying a greater effect of fosinopril than atenolol in reducing central blood pressure than is apparent from measurements of peripheral pressure. Left ventricular mass was only slightly elevated in these mild hypertensive patients and was not altered after 8 weeks of treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Koren, M. J., Devereux, R. B., Casale, P. N., Savage, D. D., & Laragh, J. H. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-5-345 · Cited by 2,366
KELLY, R. P., GIBS, H. H., O'ROURKE, M. F., DALEY, J. E., MANG, K., MORGEN, J. J., & AVOLID, A. P. (1990) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a059669 · Cited by 312
Lauer, M. S., Anderson, K. M., & Levy, D. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90549-o · Cited by 143
Cited by
The CAFE Investigators, CAFE Steering Committee and Writing Committee, Williams, B., Lacy, P. S., Thom, S. M., Cruickshank, K., Stanton, A., Collier, D., Hughes, A. D., Thurston, H., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.595496 · Cited by 1,645
Pauca, A. L., O’Rourke, M. F., & Kon, N. D. (2001) · Hypertension · doi:10.1161/hy1001.096106 · Cited by 1,179
Olsen, M. H., Angell, S. Y., Asma, S., Boutouyrie, P., Burger, D., Chirinos, J. A., Damasceno, A., Delles, C., Gimenez-Roqueplo, A.-P., Hering, D., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31134-5 · Cited by 939
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Noninvasive Assessment of Arterial Stiffness and Risk of Atherosclerotic Events
Oliver, J. J., & Webb, D. J. (2003) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000060460.52916.d6 · Cited by 823
A meta-analysis of the effects of treatment on left ventricular mass in essential hypertension
Klingbeil, A. U., Schneider, M., Martus, P., Messerli, F. H., & Schmieder, R. E. (2003) · The American Journal of Medicine · doi:10.1016/s0002-9343(03)00158-x · Cited by 761
O'Rourke, M. F., Pauca, A., & Jiang, X. (2001) · British Journal of Clinical Pharmacology · doi:10.1046/j.0306-5251.2001.01400.x · Cited by 640
Asmar, R. G., London, G. M., O’Rourke, M. E., Safar, M. E., & for the REASON Project coordinators and investigators (2001) · Hypertension · doi:10.1161/hy1001.095774 · Cited by 449
Chen, C.-H., Ting, C.-T., Nussbacher, A., Nevo, E., Kass, D. A., Pak, P., Wang, S.-P., Chang, M.-S., & Yin, F. C. P. (1996) · Hypertension · doi:10.1161/01.hyp.27.2.168 · Cited by 401
Self-citationLondon, G. M., Asmar, R. G., O'Rourke, M. F., & Safar, M. E. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.07.039 · Cited by 325
Fagard, R. H., Celis, H., Thijs, L., & Wouters, S. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.136655 · Cited by 314
Jani, B., & Rajkumar, C. (2006) · Postgraduate Medical Journal · doi:10.1136/pgmj.2005.036053 · Cited by 308
Pulse wave analysis and pulse wave velocity: a critical review of their strengths and weaknesses
Davies, J. I., & Struthers, A. D. (2003) · Journal of Hypertension · doi:10.1097/00004872-200303000-00004 · Cited by 289
Domanski, M. J., Mitchell, G. F., Norman, J. E., Exner, D. V., Pitt, B., & Pfeffer, M. A. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00679-2 · Cited by 263
A comparison of atenolol and nebivolol in isolated systolic hypertension
Dhakam, Z., Yasmin, McEniery, C. M., Burton, T., Brown, M. J., & Wilkinson, I. B. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282f283c9 · Cited by 197
Shahin, Y., Khan, J. A., & Chetter, I. (2012) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2011.12.005 · Cited by 187
“The mean systolic blood pressure ranged from 120 mmHg [9] to 176 mmHg [17] and the mean diastolic blood pressure ranged from 69 mmHg [8] to 105 mmHg [25] at baseline.”
BackgroundMethodInfluentialGenesis of the normal and abnormal arterial pulse
Vlachopoulos, C., & O'Rourke, M. (2000) · Current Problems in Cardiology · doi:10.1067/mcd.2000.104057 · Cited by 125
Manisty, C. H., & Hughes, A. D. (2013) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.2012.04342.x · Cited by 99
McGaughey, T. J., Fletcher, E. A., & Shah, S. A. (2016) · American Journal of Hypertension · doi:10.1093/ajh/hpv134 · Cited by 40
Metadata
- Authors
- Chen, C.-H., Ting, C.-T., Lin, S.-J., Hsu, T.-L., Yin, F. C. P., Siu, C. O., Chou, P., Wang, S.-P., & Chang, M.-S.
- Venue
- Hypertension
- Published
- 1995-05
- Volume
- 25
- Issue
- 5
- Pages
- 1034-1041
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2077739986
- Cited by
- 149
- References
- 3
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.