The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Noninvasive Computerized Tail-Cuff System for Measuring Blood Pressure in Mice
Abstract
Abstract We have validated a noninvasive computerized tail-cuff system for measuring blood pressure in mice. The system was designed to perform all functions automatically, including a programmable routine of cuff inflation and deflation, analysis and assignment of pulse rate and blood pressure, and recording of data electronically. To evaluate this system over a range of blood pressures, we gave groups of mice enalapril or N G -nitro- l -arginine methyl ester in their drinking water. For each of these groups, an equal number of control mice were given nothing in their drinking water. Tail-cuff blood pressures were recorded as the means of blood pressures determined on at least 3 days after at least 7 days of training. Tail-cuff enalapril and control group means were measured both 3 and 4 months after enalapril (or no drug) was begun; the group means at 3 months were not significantly different from the group means at 4 months. These results demonstrate that the system gives reproducible results. After the tail-cuff measurements were completed, intra-arterial blood pressures were attempted in all mice under unrestrained, unanesthetized conditions, and individual mouse (n=22) blood pressures with the use of the two methods were compared. The blood pressures from individual mice by tail-cuff and intra-arterial methods were highly correlated ( r =.86, P <.01). The means for the four mouse groups were also highly correlated ( r =.98, P <.02). These data show that blood pressures measured on trained mice by a computerized noninvasive tail-cuff system are reproducible and correlate well with intra-arterial blood pressures measured on unrestrained, unanesthetized mice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous Hypercholesterolemia and Arterial Lesions in Mice Lacking Apolipoprotein E
Zhang, S. H., Reddick, R. L., Piedrahita, J. A., & Maeda, N. (1992) · Science · doi:10.1126/science.1411543 · Cited by 2,237
Cited by
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Loffredo, F. S., Steinhauser, M. L., Jay, S. M., Gannon, J., Pancoast, J. R., Yalamanchi, P., Sinha, M., Dall’Osso, C., Khong, D., Shadrach, J. L., et al. (2013) · Cell · doi:10.1016/j.cell.2013.04.015 · Cited by 948
“Micewere joined for 10weeks, and during this period, we performed noninvasive blood pressure measurements using a computerized tail-cuff system (BP-2000; Visitech Systems, Apex, NC, USA) (Krege et al., 1995) that wemodified to hold parabiotic mice (Figure 3A).”
Citric acid cycle intermediates as ligands for orphan G-protein-coupled receptors
He, W., Miao, F. J.-P., Lin, D. C.-H., Schwandner, R. T., Wang, Z., Gao, J., Chen, J.-L., Tian, H., & Ling, L. (2004) · Nature · doi:10.1038/nature02488 · Cited by 909
Howell, G. R., Macalinao, D. G., Sousa, G. L., Walden, M., Soto, I., Kneeland, S. C., Barbay, J. M., King, B. L., Marchant, J. K., Hibbs, M., et al. (2011) · Journal of Clinical Investigation · doi:10.1172/jci44646 · Cited by 473
Metadata
- Authors
- Krege, J. H., Hodgin, J. B., Hagaman, J. R., & Smithies, O.
- Venue
- Hypertension
- Published
- 1995-05
- Volume
- 25
- Issue
- 5
- Pages
- 1111-1115
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2051124233
- Cited by
- 587
- References
- 1
- FWCI
- 7.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Noninvasive Computerized Tail-Cuff System for Measuring Blood Pressure in Mice. https://app.cochat.ai/papers/10.1161/01.hyp.25.5.1111
- The paper
- Krege, J. H., Hodgin, J. B., Hagaman, J. R., & Smithies, O. (1995). A Noninvasive Computerized Tail-Cuff System for Measuring Blood Pressure in Mice. Hypertension. https://doi.org/10.1161/01.hyp.25.5.1111
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.