CoChat

Evaluation of the Technique Used by Health-Care Workers for Taking Blood Pressure

Villegas, Iván, Arias, Isabel C., Botero, Adriana, Escobar, Alejandro · 1995 · Hypertension
Cited by 102

The DOI matches its Crossref record.

Abstract

The precise guidelines recommended by the American Heart Association for blood pressure measurement are commonly overlooked by health-care workers, who generally take blood pressure in an arbitrary way. To validate this observation we designed a descriptive and observational study to be carried out in a major hospital. One hundred and seventy-two health-care workers divided into four groups (63 general practitioners, 25 clinical and 25 surgical specialists, and 59 nurses) were evaluated in a two-part test. In the first part (practical), the examinee had to follow all the steps recommended by the American Heart Association to get a passing score. In the second part (theoretical, which came second to avoid influencing the practical), the examinee had to answer correctly 7 of 10 questions based on the American Heart Association’s guidelines to obtain a passing score. The highest accepted variation in systolic and diastolic pressures between examinee and observer was ±4 mm Hg. None of the examinees followed the American Heart Association’s recommendations. Sixty-three percent of systolic and 53% of diastolic readings were out of range. Surgical specialists obtained the best practical results (48% systolic and 64% diastolic within range), and nurses obtained the lowest values (29% and 39%, respectively; P =.03 versus surgical specialists). These two groups showed deficiencies in the theoretical test (nurses, 10% correct answers and surgical specialists, 16%). Clinical specialists obtained the best results on the theoretical test (60% correct; P <.05 versus the other groups) but were deficient in the practical test (32% systolic and 60% diastolic within range). In conclusion, on practical and theoretical bases health-care workers took blood pressure inaccurately and incorrectly.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.26.6.1204

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 102

Metadata

Authors
Villegas, I., Arias, I. C., Botero, A., & Escobar, A.
Venue
Hypertension
Published
1995-12
Volume
26
Issue
6
Pages
1204-1206
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2107746949
Cited by
102
References
0
FWCI
0.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the Technique Used by Health-Care Workers for Taking Blood Pressure. https://app.cochat.ai/papers/10.1161/01.hyp.26.6.1204
The paper
Villegas, I., Arias, I. C., Botero, A., & Escobar, A. (1995). Evaluation of the Technique Used by Health-Care Workers for Taking Blood Pressure. Hypertension. https://doi.org/10.1161/01.hyp.26.6.1204

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.