CoChat

Difference Between Clinic and Daytime Blood Pressure Is Not a Measure of the White Coat Effect

Open access
Parati, Gianfranco, Ulian, Luisa, Santucciu, Cinzia, Omboni, Stefano, Mancia, Giuseppe · 1998 · Hypertension
Cited by 152

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Abstract —The purpose of the present study was to evaluate whether the difference between blood pressure measured in the clinic or physician’s office and the average daytime blood pressure accurately reflects the blood pressure response of the patient to the physician (“white coat effect” or “white coat hypertension”). We studied 28 hypertensive outpatients (mean age, 41.8±11.2 years; age range, 21 to 64 years) of 35 consecutive patients attending our hypertension clinic, in whom (1) continuous noninvasive finger blood pressure was recorded before and during the visit, (2) blood pressure was measured according to the Riva-Rocci-Korotkoff method (mercury sphygmomanometer) with the patient in the supine position, and (3) daytime ambulatory blood pressure was monitored with a SpaceLabs 90207 device. The peak blood pressure increase recorded directly during the visit was compared with the difference between clinic and daytime average ambulatory blood pressures. Compared with previsit values, peak increases in finger systolic and diastolic blood pressures during the visit to the clinic were 38.2±3.1 and 20.7±1.6 mm Hg, respectively (mean±SEM, P <.01 for both). Daytime average systolic and diastolic blood pressures were 135.5±2.5 and 89.2±1.9 mm Hg, with both lower than the corresponding clinic blood pressure values (146.6±3.6 and 94.9±2.2 mm Hg, P <.01). These differences, however, were <30% of the peak finger blood pressure increases during the physician’s visit, to which these increases showed no relation. Although the visit to the physician’s office was associated with tachycardia (9.0±1.6 bpm, P <.01), there was no difference between clinic and daytime average heart rates. These data indicate that the clinic−daytime average blood pressure difference does not reflect the alerting reaction and the pressure response elicited by the physician’s visit and thus is not a reliable measure of the white coat effect.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.31.5.1185

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 152

Metadata

Authors
Parati, G., Ulian, L., Santucciu, C., Omboni, S., & Mancia, G.
Venue
Hypertension
Published
1998-05
Volume
31
Issue
5
Pages
1185-1189
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2140281675
Cited by
152
References
3
FWCI
4.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Difference Between Clinic and Daytime Blood Pressure Is Not a Measure of the White Coat Effect. https://app.cochat.ai/papers/10.1161/01.hyp.31.5.1185
The paper
Parati, G., Ulian, L., Santucciu, C., Omboni, S., & Mancia, G. (1998). Difference Between Clinic and Daytime Blood Pressure Is Not a Measure of the White Coat Effect. Hypertension. https://doi.org/10.1161/01.hyp.31.5.1185

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.