Diagnosis of White Coat Hypertension by Ambulatory Blood Pressure Monitoring

Owens, Patrick, Atkins, Neil, O’Brien, Eoin · 1999 · Hypertension
Cited by 137

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Abstract —White coat hypertension (WCH) is common in referred hypertensive patients. Ambulatory blood pressure monitoring (ABPM) is not free from the white coat syndrome. We examined the use of the elevation of the first and last measurements of ABPM for diagnosis of WCH in a hypertensive population that had been referred to a hospital-based hypertension unit. Data were obtained on 1350 patients for clinic and ABPM parameters. WCH, as diagnosed by conventional clinic blood pressure (BP) measurement, was compared with a variety of alternative methods determined from ABPM. In all cases, mean daytime pressure was <135 mm Hg/85 mm Hg with an elevation of clinic BP ≥140 mm Hg systolic or 90 mm Hg diastolic. The definitions tested for this elevation were first hour mean pressure, first reading, maximum reading in first hour, last hour mean pressure, last reading, maximum reading in the last hour and maximum reading in first or last hour. Elevation of the maximum pressure in the first hour or last hour above 140 mm Hg systolic or 90 mm Hg diastolic showed a high level of agreement (κ=0.91) with classical WCH for diagnosis of the white coat syndrome. Termed ambulatory white coat hypertension, patients with this finding were older than classic white coat patients and had higher daytime (127±6/78±5 mm Hg versus 121±5.5/74±6 mm Hg, P <0.005 for systolic and diastolic) and nighttime (114±11/67±8 mm Hg versus 106±9/61±6 mm Hg, P <0.005 for systolic and diastolic) pressures. They also had a significantly greater Sokolow-Lyon index (leads V 1 +V 5 , 21±7 mV versus 18±6 mV). Elevation of BP above 140 mm Hg systolic or 90 mm Hg diastolic in the first or last hour of monitoring diagnoses patients with a white coat response in whom there is a higher BP profile than in patients with classic white coat response alone. We suggest, therefore, that this is a better measure of the white coat phenomenon.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.34.2.267

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Owens, P., Atkins, N., & O’Brien, E.
Venue
Hypertension
Published
1999-08
Volume
34
Issue
2
Pages
267-272
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2146172162
Cited by
137
References
1
FWCI
3.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.