Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 349

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Ambulatory Blood Pressure: Normality and Comparison With Other Measurements

Schettini, Carlos, Bianchi, Manuel, Nieto, Fernando, Sandoya, Edgardo, Senra, Hugo·1999·Hypertension

Abstract

Abstract —Previous studies have reported results on 24-hour ambulatory blood pressure (ABP) in Europe and Japan, but no data exists from South America. In this study, we conducted a population survey to identify reference values and to compare ambulatory blood pressure with clinic, home, and self-measured values. A random sample of 2650 adults was selected among 190 000 people covered by our prepaid healthcare institution. Clinic (physician and nurse) and home (nurse) blood pressure measurements were performed 3 times each, with semiautomatic electronic equipment. Self-measurements were performed by the subjects manually activating the ambulatory device. We analyzed 1573 individuals who were not receiving antihypertensive therapy from 1921 participants. Self-measurement was available in a subgroup of 577 participants younger than the whole sample. Normal ambulatory blood pressure limits were estimated as those that best correlated with 140/90 mm Hg at clinic. Estimated values were 125/80 mm Hg for 24-hour ambulatory (range: 122 to 128 and 77 to 83 mm Hg) and 129/84 mm Hg for daytime ambulatory (range: 127 to 132 and 81 to 86) blood pressure, depending on gender and age. Ambulatory and clinic blood pressures increased with age. The age-dependent increase in ABP was similar in women and men. Average blood pressure at clinic was 124/79 mm Hg by physician and 123/78 mm Hg by nurse. Nurse measurement at home was 125/78 mm Hg, daytime ambulatory was 121/77 mm Hg, and 24-hour ambulatory was 118/74 mm Hg. The values of the subgroup with self-measurement were physician 119/77 mm Hg; nurse at clinic 118/77 mm Hg; nurse at home 121/78 mm Hg; self-measured 115/72 mm Hg; daytime ambulatory 119/77 mm Hg; and 24-hour ambulatory 115/73 mm Hg. This study shows that a 24-hour ABP average value of 125/80 mm Hg and a daytime ABP average value of 129/84 mm Hg are suitable upper limits for normality. Higher limits would yield an artificially higher prevalence of white coat hypertension. Most subjects showed higher blood pressure levels when measurements were performed by healthcare personnel at a clinic or at home than when self-measured at home.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.34.4.818

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 349

Metadata

Authors
Schettini, C., Bianchi, M., Nieto, F., Sandoya, E., & Senra, H.
Venue
Hypertension
Published
1999-10
Volume
34
Issue
4
Pages
818-825
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2580466971
Cited by
349
References
11
FWCI
12.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ambulatory Blood Pressure: Normality and Comparison With Other Measurements. https://app.cochat.ai/papers/10.1161/01.hyp.34.4.818
The paper
Schettini, C., Bianchi, M., Nieto, F., Sandoya, E., & Senra, H. (1999). Ambulatory Blood Pressure: Normality and Comparison With Other Measurements. Hypertension. https://doi.org/10.1161/01.hyp.34.4.818

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.