Action Potential Duration Restitution and Alternans in Rabbit Ventricular Myocytes: The Key Role of Intracellular Calcium Cycling
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Action potential duration (APD) restitution properties and repolarization alternans are thought to be important arrhythmogenic factors. We investigated the role of intracellular calcium (Ca 2+ i ) cycling in regulating APD restitution slope and repolarization (APD) alternans in patch-clamped rabbit ventricular myocytes at 34 to 36°C, using the perforated or ruptured patch clamp techniques with Fura-2-AM to record Ca 2+ i . When APD restitution was measured by either the standard extrastimulus (S1S2) method or the dynamic rapid pacing method, the maximum APD restitution slope exceeded 1 by both methods, but was more shallow with the dynamic method. These differences were associated with greater Ca 2+ i accumulation during dynamic pacing. The onset of APD alternans occurred at diastolic intervals at which the APD restitution slope was significantly <1 and was abolished by suppressing sarcoplasmic reticulum (SR) Ca 2+ i cycling with thapsigargin and ryanodine, or buffering the global Ca 2+ i transient with BAPTA-AM or BAPTA. Thapsigargin and ryanodine flattened APD restitution slope to <1 when measured by the dynamic method, but not by the S1S2 method. BAPTA-AM or BAPTA failed to flatten APD restitution slope to <1 by either method. In conclusion, APD alternans requires intact Ca 2+ i cycling and is not reliably predicted by APD restitution slope when Ca 2+ i cycling is suppressed. Ca 2+ i cycling may contribute to differences between APD restitution curves measured by S1S2 versus dynamic pacing protocols by inducing short-term memory effects related to pacing-dependent Ca 2+ i accumulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new generation of Ca2+ indicators with greatly improved fluorescence properties.
Grynkiewicz, G., Poenie, M., & Tsien, R. Y. (1985) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)83641-4 · Cited by 21,607
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
Excitation-Contraction Coupling and Cardiac Contractile Force
Bers, D. M., & Zhu, Y. (2010) · Journal of Cardiovascular Disease Research · doi:10.1016/s0975-3583(10)11011-0 · Cited by 1,603
Excitation-Contraction Coupling and Cardiac Contractile Force
Bers, D. M. (2001) · Developments in Cardiovascular Medicine · doi:10.1007/978-94-010-0658-3 · Cited by 1,548
Electrical Alternans and Vulnerability to Ventricular Arrhythmias
Rosenbaum, D. S., Jackson, L. E., Smith, J. M., Garan, H., Ruskin, J. N., & Cohen, R. J. (1994) · New England Journal of Medicine · doi:10.1056/nejm199401273300402 · Cited by 1,143
Low access resistance perforated patch recordings using amphotericin B
Rae, J., Cooper, K., Gates, P., & Watsky, M. (1991) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(91)90017-t · Cited by 917
Guevara, M. R., Glass, L., & Shrier, A. (1981) · Science · doi:10.1126/science.7313693 · Cited by 551
Preventing ventricular fibrillation by flattening cardiac restitution
Garfinkel, A., Kim, Y.-H., Voroshilovsky, O., Qu, Z., Kil, J. R., Lee, M.-H., Karagueuzian, H. S., Weiss, J. N., & Chen, P.-S. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.090492697 · Cited by 530
Self-citationElectrical alternans and spiral wave breakup in cardiac tissue
Karma, A. (1994) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166024 · Cited by 479
Electrical Restitution and Spatiotemporal Organization During Ventricular Fibrillation
Riccio, M. L., Koller, M. L., & Gilmour, R. F. (1999) · Circulation Research · doi:10.1161/01.res.84.8.955 · Cited by 366
Cited by
Cheng, H., & Lederer, W. J. (2008) · Physiological Reviews · doi:10.1152/physrev.00030.2007 · Cited by 552
Mechanisms of sudden cardiac death
Rubart, M. (2005) · Journal of Clinical Investigation · doi:10.1172/jci26381 · Cited by 504
A Rabbit Ventricular Action Potential Model Replicating Cardiac Dynamics at Rapid Heart Rates
Mahajan, A., Shiferaw, Y., Sato, D., Baher, A., Olcese, R., Xie, L.-H., Yang, M.-J., Chen, P.-S., Restrepo, J. G., Karma, A., et al. (2008) · Biophysical Journal · doi:10.1529/biophysj.106.98160 · Cited by 403
Self-citationter Keurs, H. E. D. J., & Boyden, P. A. (2007) · Physiological Reviews · doi:10.1152/physrev.00011.2006 · Cited by 356
The Dynamics of Cardiac Fibrillation
Weiss, J. N., Qu, Z., Chen, P.-S., Lin, S.-F., Karagueuzian, H. S., Hayashi, H., Garfinkel, A., & Karma, A. (2005) · Circulation · doi:10.1161/circulationaha.104.529545 · Cited by 316
Self-citationLehnart, S. E., Ackerman, M. J., Benson, D. W., Brugada, R., Clancy, C. E., Donahue, J. K., George, A. L., Grant, A. O., Groft, S. C., January, C. T., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.711689 · Cited by 254
Myofilament Ca2+ sensitization causes susceptibility to cardiac arrhythmia in mice
Baudenbacher, F., Schober, T., Pinto, J. R., Sidorov, V. Y., Hilliard, F., Solaro, R. J., Potter, J. D., & Knollmann, B. C. (2008) · Journal of Clinical Investigation · doi:10.1172/jci36642 · Cited by 248
Stabilization of cardiac ryanodine receptor prevents intracellular calcium leak and arrhythmias
Lehnart, S. E., Terrenoire, C., Reiken, S., Wehrens, X. H. T., Song, L.-S., Tillman, E. J., Mancarella, S., Coromilas, J., Lederer, W. J., Kass, R. S., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602133103 · Cited by 230
Nonlinear and stochastic dynamics in the heart
Qu, Z., Hu, G., Garfinkel, A., & Weiss, J. N. (2014) · Physics Reports · doi:10.1016/j.physrep.2014.05.002 · Cited by 220
Self-citationNg, G. A., Brack, K. E., Patel, V. H., & Coote, J. H. (2007) · Cardiovascular Research · doi:10.1016/j.cardiores.2006.12.001 · Cited by 203
“The cellular mechanisms underlying alternans are complex, with Ca homeostasis being implicated together with changes in transmembrane ion channel activities [18,20,40].”
BackgroundResultAlternans and Arrhythmias: From Cell to Heart
Weiss, J. N., Nivala, M., Garfinkel, A., & Qu, Z. (2011) · Circulation Research · doi:10.1161/circresaha.110.223586 · Cited by 161
Self-citationWang, J., Chen, A., Lieu, D. K., Karakikes, I., Chen, G., Keung, W., Chan, C. W., Hajjar, R. J., Costa, K. D., Khine, M., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.039 · Cited by 69
“calcium-dependent parameter crucial for spiral wave stability [35].”
Background
Metadata
- Authors
- Goldhaber, J. I., Xie, L.-H., Duong, T., Motter, C., Khuu, K., & Weiss, J. N.
- Venue
- Circulation Research
- Published
- 2005-03-04
- Volume
- 96
- Issue
- 4
- Pages
- 459-466
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2111174244
- Cited by
- 235
- References
- 37
- FWCI
- 15.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.