The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
The Range of Adaptation by Collateral Vessels After Femoral Artery Occlusion
Open accessAbstract
Natural adaptation to femoral artery occlusion in animals by collateral artery growth restores only ≈35% of adenosine-recruitable maximal conductance (C max ) probably because initially elevated fluid shear stress (FSS) quickly normalizes. We tested the hypothesis whether this deficit can be mended by artificially increasing FSS or whether anatomical restraints prevent complete restitution. We chronically increased FSS by draining the collateral flow directly into the venous system by a side-to-side anastomosis between the distal stump of the occluded femoral artery and the accompanying vein. After reclosure of the shunt collateral flow was measured at maximal vasodilatation. C max reached 100% already at day 7 and had, after 4 weeks, surpassed (2-fold) the C max of the normal vasculature before occlusion. Expression profiling showed upregulation of members of the Rho-pathway (RhoA, cofilin, focal adhesion kinase, vimentin) and the Rho-antagonist Fasudil markedly inhibited arteriogenesis. The activities of Ras and ERK-1,-2 were markedly increased in collateral vessels of the shunt experiment, and infusions of L-NAME and L-NNA strongly inhibited MAPK activity as well as shunt-induced arteriogenesis. Infusions of the peroxinitrite donor Sin-1 inhibited arteriogenesis. The radical scavengers urate, ebselen, SOD, and catalase had no effect. We conclude that increased FSS can overcome the anatomical restrictions of collateral arteries and is potentially able to completely restore maximal collateral conductance. Increased FSS activates the Ras-ERK-, the Rho-, and the NO- (but not the Akt-) pathway enabling collateral artery growth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Endothelial dysfunction in cardiovascular diseases: the role of oxidant stress
Cai, H., & Harrison, D. G. (2000) · Circulation Research · doi:10.1161/01.res.87.10.840 · Cited by 3,839
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Cited by
Evaluation of postnatal arteriogenesis and angiogenesis in a mouse model of hind-limb ischemia
Limbourg, A., Korff, T., Napp, L. C., Schaper, W., Drexler, H., & Limbourg, F. P. (2009) · Nature Protocols · doi:10.1038/nprot.2009.185 · Cited by 405
Self-citationCollateral circulation: Past and present
Schaper, W. (2009) · Basic Research in Cardiology · doi:10.1007/s00395-008-0760-x · Cited by 388
Self-citationVascular remodeling after ischemic stroke: mechanisms and therapeutic potentials.
Liu, J., Wang, Y., Akamatsu, Y., Lee, C. C., Stetler, R. A., Lawton, M. T., & Yang, G.-Y. (2014) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2013.11.004 · Cited by 335
Postischemic Revascularization: From Cellular and Molecular Mechanisms to Clinical Applications
Silvestre, J.-S., Smadja, D. M., & Lévy, B. I. (2013) · Physiological Reviews · doi:10.1152/physrev.00006.2013 · Cited by 255
Metadata
- Authors
- Eitenmüller, I., Volger, O., Kluge, A., Troidl, K., Barancik, M., Cai, W.-J., Heil, M., Pipp, F., Fischer, S., Horrevoets, A. J. G., Schmitz-Rixen, T., & Schaper, W.
- Venue
- Circulation Research
- Published
- 2006-09-15
- Volume
- 99
- Issue
- 6
- Pages
- 656-662
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2107006878
- Cited by
- 202
- References
- 2
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Range of Adaptation by Collateral Vessels After Femoral Artery Occlusion. https://app.cochat.ai/papers/10.1161/01.res.0000242560.77512.dd
- The paper
- Eitenmüller, I., Volger, O., Kluge, A., Troidl, K., Barancik, M., Cai, W.-J., Heil, M., Pipp, F., Fischer, S., Horrevoets, A. J. G., Schmitz-Rixen, T., & Schaper, W. (2006). The Range of Adaptation by Collateral Vessels After Femoral Artery Occlusion. Circulation Research. https://doi.org/10.1161/01.res.0000242560.77512.dd
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.