A Concept of Negative Interstitial Pressure Based on Pressures in Implanted Perforated Capsules
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Over 200 perforated plastic capsules were implanted in different tissues of the dog, and the wounds were allowed to heal. After one month, pressures measured by inserting a needle through the skin and then through a perforation of the capsule into its cavity were always negative in normal tissues, averaging-6.4 mm Hg. The pressure was always positive in edematous tissues. Evidence is presented to indicate that the pressure measured in the capsule is equal to, or nearly equal to, the interstitial fluid pressure in the tissue spaces surrounding the capsule. On the other hand, pressure measurements made by a needle technic failed except in rare instances to give negative values in normal tissues but in edematous tissues gave almost exactly the same values as those recorded by the capsules. Also, pressures measured by the capsules changed in accordance with Starling's law of the capillaries when (a) venous pressure was raised, (b) when arterial pressure was lowered, (c) when the tissues were dehydrated by intravenous infusion of dextran, or (d) when the tissues were hydrated by intravenous infusion of saline. Pressures measured by a needle technique failed to change in accordance with this law in these same experiments. Therefore, it is concluded that needle pressure determinations in non-edematous tissue do not measure the interstitial fluid pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
On the Absorption of Fluids from the Connective Tissue Spaces
Starling, E. H. (1896) · The Journal of Physiology · doi:10.1113/jphysiol.1896.sp000596 · Cited by 2,148
Passage of Molecules Through Capillary Walls
Pappenheimer, J. R. (1953) · Physiological Reviews · doi:10.1152/physrev.1953.33.3.387 · Cited by 954
GUYTON, A. C., LINDSEY, A. W., JOHNNIE O., H., JOHN W., W., & MALCOLM A., F. (1959) · Circulation Research · doi:10.1161/01.res.7.4.649 · Cited by 564
Self-citationMicro-injection studies of capillary blood pressure in human skin
Landis, E. M. (1930) · Medical Entomology and Zoology · Cited by 481
Vascular Patterns and Active Vasomotion as Determiners of Flow Through Minute Vessels
Nicoll, P. A., Webb, R. L., & Lutz, B. R. (1955) · Angiology · doi:10.1177/000331975500600403 · Cited by 149
THE EFFECT OF THE PULSE UPON THE FORMATION AND FLOW OF LYMPH
Parsons, R. J., & McMaster, P. D. (1938) · The Journal of Experimental Medicine · doi:10.1084/jem.68.3.353 · Cited by 144
Wells, H. S., Youmans, J. B., & Miller, D. G. (1938) · Journal of Clinical Investigation · doi:10.1172/jci100976 · Cited by 103
LYMPHATICS AND LYMPH CIRCULATION—PHYSIOLOGY AND PATHOLOGY
RUSZNYÁK, I., Földi, M., Szabó, G., & Pierre, R. L. S. (1968) · The American Journal of the Medical Sciences · doi:10.1097/00000441-196805000-00018 · Cited by 99
McMaster, P. D. (1946) · The Journal of Experimental Medicine · doi:10.1084/jem.84.5.473 · Cited by 64
Cited by
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Wiig, H., & Swartz, M. A. (2012) · Physiological Reviews · doi:10.1152/physrev.00037.2011 · Cited by 722
Guyton, A. C., Granger, H. J., & Taylor, A. E. (1971) · Physiological Reviews · doi:10.1152/physrev.1971.51.3.527 · Cited by 574
Self-citationExchange of Substances Through Capillary Walls
Renkin, E. M. (1969) · Novartis Foundation Symposia · doi:10.1002/9780470719671.ch4 · Cited by 511
Lymphatic Vessel Network Structure and Physiology
Breslin, J. W., Yang, Y., Scallan, J. P., Sweat, R. S., Adderley, S. P., & Murfee, W. L. (2018) · Comprehensive Physiology · doi:10.1002/cphy.c180015 · Cited by 341
Oncotic pressures opposing filtration across non‐fenestrated rat microvessels
Adamson, R. H., Lenz, J. F., Zhang, X., Adamson, G. N., Weinbaum, S., & Curry, F. E. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.058255 · Cited by 323
Interstitial Fluid Pressure: II. Pressure-Volume Curves of Interstitial Space
GUYTON, A. C. (1965) · Circulation Research · doi:10.1161/01.res.16.5.452 · Cited by 286
Self-citationInterstitial fluid lipoproteins.
Sloop, C. H., Dory, L., & Roheim, P. S. (1987) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)38701-0 · Cited by 228
Body Fluid Dynamics: Back to the Future
Bhave, G., & Neilson, E. G. (2011) · Journal of the American Society of Nephrology · doi:10.1681/asn.2011080865 · Cited by 215
Interstitial Pressure in Pancreatic Ductal Adenocarcinoma Is Dominated by a Gel-Fluid Phase
DuFort, C. C., DelGiorno, K. E., Carlson, M. A., Osgood, R. J., Zhao, C., Huang, Z., Thompson, C. B., Connor, R. J., Thanos, C. D., Scott Brockenbrough, J., et al. (2016) · Biophysical Journal · doi:10.1016/j.bpj.2016.03.040 · Cited by 171
“The negative pressure has been equated to a ‘‘tissue absorption’’ or ‘‘imbibition’’ pressure (16) and can exist only when the interstitium is in a dehydrated state (7,33).”
Background(1993) · PubMed · Cited by 166
A New View of Starling's Hypothesis at the Microstructural Level
Hu, X., & Weinbaum, S. (1999) · Microvascular Research · doi:10.1006/mvre.1999.2177 · Cited by 163
“Therefore, the pressure drop in regions B and C will be neglected and a uniform pressure P i is ssumed which is 22 cm H2O (Guyton, 1963).”
BackgroundSmaje, L., Zweifach, B. W., & Intaglietta, M. (1970) · Microvascular Research · doi:10.1016/0026-2862(70)90055-5 · Cited by 163
DuFort, C. C., DelGiorno, K. E., & Hingorani, S. R. (2016) · Gastroenterology · doi:10.1053/j.gastro.2016.03.040 · Cited by 144
“Pressures measured with the WN and implanted capsules in most tissues are slightly negative relative to atmosphere; these pressures are also lower than the slightly positive pressures typically measured with the micropipette.(28) This discrepancy led to invoking the presence of a solid tissue pressure from compacted t…”
Twenty‐Four Hour Variation in Flow and Composition of Leg Lymph in Normal Men
Engeset, A., Olszewski, W., Jæger, P. M., Sokolowski, J., & Theodorsen, L. (1977) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1977.tb10364.x · Cited by 78
The importance of plasma protein for blood volume and blood pressure homeostasis
Koomans, H. A., Braam, B., Geers, A. B., Roos, J. C., & Dorhout Mees, E. J. (1986) · Kidney International · doi:10.1038/ki.1986.248 · Cited by 52
Metadata
- Authors
- GUYTON, A. C., Frank, M., & Abernathy, B.
- Venue
- Circulation Research
- Published
- 1963-04
- Volume
- 12
- Issue
- 4
- Pages
- 399-414
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W1981471842
- Cited by
- 383
- References
- 10
- FWCI
- 9.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.