Pulmonary Vascular Impedance in the Dog
The DOI matches its Crossref record.
Abstract
Pulmonary vascular hydraulic input impedance was measured in 13 anesthetized openchest dogs with normal sinus rhythm, and 2 dogs with surgically induced atrioventricular block, by means of electromagnetic flowmeters and strain gauge manometers of known frequency response. The linearity of the pulmonary bed was evaluated by measuring impedance while the heart rate, and hence the pulsatile input to the bed, was varied. The pulmonary bed behaved as a quasilinear system, within the limits of accuracy of the methods employed and the range of frequencies tested. The use of input impedance, or oscillatory pressure/flow ratio, to describe some characteristics of the bed is therefore justifiable, and analogies with linear models like the simple transmission line are not unreasonable. The characteristic input impedance averaged 3,094 dyne sec cm -5 kg, or about one-third the magnitude of the pulmonary vascular resistance, and was therefore a significant part of the total opposition that must be overcome in moving blood through the lungs. This impedance to pulsatile flow is not included in calculations of resistance from mean pressure and flow measurements. The pattern of the impedance spectrum suggested that reflections originating from arteries 1.0 mm and less in diameter play a large role in determining input impedance and its variations with frequency. Pulmonary vasoconstriction by 5-hydroxytryptamine (serotonin) altered the impedance pattern in a manner consistent with increased wave reflection and displacement of the dominant reflecting sites to positions nearer the main pulmonary artery. Capillary compression by increased intra-alveolar pressure also increased reflection, but did not alter the sites of reflection significantly, providing further evidence that the normal impedance pattern and its modification by serotonin are both determined by the characteristics of the arterial part of the bed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
O’Rourke, M. F., & Safar, M. E. (2005) · Hypertension · doi:10.1161/01.hyp.0000168052.00426.65 · Cited by 1,279
The right ventricle: anatomy, physiology, and clinical importance
Dell'Italia, L. J. (1991) · Current Problems in Cardiology · doi:10.1016/0146-2806(91)90009-y · Cited by 300
Input Impedance of the Systemic Circulation
O'ROURKE, M. F., & TAYLOR, M. G. (1967) · Circulation Research · doi:10.1161/01.res.20.4.365 · Cited by 282
Pulmonary Arterial Pulse Wave Velocity and Impedance in Man
Milnor, W. R., Conti, C. R., Lewis, K. B., & O'Rourke, M. F. (1969) · Circulation Research · doi:10.1161/01.res.25.6.637 · Cited by 238
Self-citationHydraulic Power Associated with Pulmonary Blood Flow and its Relation to Heart Rate
MILNOR, W. R., BERGEL, D. H., & BARGAINER, J. D. (1966) · Circulation Research · doi:10.1161/01.res.19.3.467 · Cited by 197
Self-citationEchocardiographic Indexes for the Non-Invasive Evaluation of Pulmonary Hemodynamics
Milan, A., Magnino, C., & Veglio, F. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.01.003 · Cited by 174
Metadata
- Authors
- BERGEL, D. H., & MILNOR, W. R.
- Venue
- Circulation Research
- Published
- 1965-05
- Volume
- 16
- Issue
- 5
- Pages
- 401-415
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2077075204
- Cited by
- 217
- References
- 0
- FWCI
- 25.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.