The DOI matches its Crossref record.
Input Impedance of the Systemic Circulation
Open accessAbstract
The hydraulic load presented to the left ventricle by the systemic circulation was characterized by expressing pressure-flow relationships in the ascending aorta as input impedance. This was determined by spectral or Fourier analysis of simultaneously recorded pressure and flow waves in 1 unanesthetized and 27 anesthetized dogs. Impedance modulus fell steeply from its value at zero frequency (the peripheral resistance) and its value was lowest (less than 1/20th of the peripheral resistance) over that band of frequencies (usually between 1.5 and 10 cycle/sec) which contained most of the energy of the left ventricular ejection (flow) wave. The patterns of modulus and phase of ascending aortic impedance were found to result from the presence of two functionally discrete reflecting sites in the systemic circulation, one in the upper part of the body and the other in the lower. The presence of these two sites appears to be an important factor in maintaining a low impedance modulus between 1.5 and 10 cycle/sec, and so in providing a favorable impedance to pulsatile flow from the heart. Both modulus and phase of impedance in the ascending aorta showed changes similar to those seen in other arteries when blood pressure was altered and when vasodilation occurred in the vascular bed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechanical Factors in Arterial Aging
O’Rourke, M. F., & Hashimoto, J. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.12.050 · Cited by 1,250
Self-citationAnalog studies of the human systemic arterial tree
Westerhof, N., Bosman, F., De Vries, C. J., & Noordergraaf, A. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90024-4 · Cited by 684
O’Rourke, M. F., & Nichols, W. W. (2005) · Hypertension · doi:10.1161/01.hyp.0000153793.84859.b8 · Cited by 543
Self-citationVentricular efficiency predicted by an analytical model
Burkhoff, D., & Sagawa, K. (1986) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1986.250.6.r1021 · Cited by 405
Mechanical Principles in Arterial Disease
O’Rourke, M. (1995) · Hypertension · doi:10.1161/01.hyp.26.1.2 · Cited by 401
Self-citation
Metadata
- Authors
- O'ROURKE, M. F., & TAYLOR, M. G.
- Venue
- Circulation Research
- Published
- 1967-04
- Volume
- 20
- Issue
- 4
- Pages
- 365-380
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W1967118204
- Cited by
- 282
- References
- 0
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Input Impedance of the Systemic Circulation. https://app.cochat.ai/papers/10.1161/01.res.20.4.365
- The paper
- O'ROURKE, M. F., & TAYLOR, M. G. (1967). Input Impedance of the Systemic Circulation. Circulation Research. https://doi.org/10.1161/01.res.20.4.365
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.