Input Impedance of the Systemic Circulation
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The hydraulic load presented to the left ventricle by the systemic circulation was characterized by expressing pressure-flow relationships in the ascending aorta as input impedance. This was determined by spectral or Fourier analysis of simultaneously recorded pressure and flow waves in 1 unanesthetized and 27 anesthetized dogs. Impedance modulus fell steeply from its value at zero frequency (the peripheral resistance) and its value was lowest (less than 1/20th of the peripheral resistance) over that band of frequencies (usually between 1.5 and 10 cycle/sec) which contained most of the energy of the left ventricular ejection (flow) wave. The patterns of modulus and phase of ascending aortic impedance were found to result from the presence of two functionally discrete reflecting sites in the systemic circulation, one in the upper part of the body and the other in the lower. The presence of these two sites appears to be an important factor in maintaining a low impedance modulus between 1.5 and 10 cycle/sec, and so in providing a favorable impedance to pulsatile flow from the heart. Both modulus and phase of impedance in the ascending aorta showed changes similar to those seen in other arteries when blood pressure was altered and when vasodilation occurred in the vascular bed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald, D. A. (1963) · The American Journal of the Medical Sciences · doi:10.1097/00000441-196301000-00017 · Cited by 1,565
Pulmonary Vascular Impedance in the Dog
BERGEL, D. H., & MILNOR, W. R. (1965) · Circulation Research · doi:10.1161/01.res.16.5.401 · Cited by 217
The Input Impedance of an Assembly of Randomly Branching Elastic Tubes
Taylor, M. G. (1966) · Biophysical Journal · doi:10.1016/s0006-3495(66)86638-9 · Cited by 200
Self-citationVascular Impedance of the Femoral Bed
O’Rourke, M. F., & Taylor, M. G. (1966) · Circulation Research · doi:10.1161/01.res.18.2.126 · Cited by 186
Self-citationAN EXPERIMENTAL STUDY OF THE STANDING WAVES IN THE PULSE PROPAGATED THROUGH THE AORTA
Hamilton, W. F., & Dow, P. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.125.1.48 · Cited by 175
Taylor, M. G. (1966) · Circulation Research · doi:10.1161/01.res.18.5.585 · Cited by 134
Self-citationThe Hydrodynamics of the Arterial Circulation
McDonald, D. A., & Taylor, M. G. (1959) · Progress in Biophysics and Biophysical Chemistry · doi:10.1016/s0096-4174(18)30167-7 · Cited by 129
Self-citationThe relation of pulsatile pressure and flow in the pulmonary vascular bed
Caro, C. G., & McDonald, D. A. (1961) · The Journal of Physiology · doi:10.1113/jphysiol.1961.sp006734 · Cited by 85
An Approach to an Analysis of the Arterial Pulse Wave II. Fluid Oscillations in an Elastic Pipe
Taylor, M. G. (1957) · Physics in Medicine & Biology · doi:10.1088/0031-9155/1/4/302 · Cited by 79
Self-citationWave-travel in a Non-uniform Transmission Line, in Relation to Pulses in Arteries
Taylor, M. G. (1965) · Physics in Medicine and Biology · doi:10.1088/0031-9155/10/4/308 · Cited by 66
Self-citation
Cited by
Mechanical Factors in Arterial Aging
O’Rourke, M. F., & Hashimoto, J. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.12.050 · Cited by 1,250
Self-citationThe influence of heart rate on augmentation index and central arterial pressure in humans
Wilkinson, I. B., MacCallum, H., Flint, L., Cockcroft, J. R., Newby, D. E., & Webb, D. J. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00263.x · Cited by 1,091
Analog studies of the human systemic arterial tree
Westerhof, N., Bosman, F., De Vries, C. J., & Noordergraaf, A. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90024-4 · Cited by 684
O’Rourke, M. F., & Nichols, W. W. (2005) · Hypertension · doi:10.1161/01.hyp.0000153793.84859.b8 · Cited by 543
Self-citationVentricular efficiency predicted by an analytical model
Burkhoff, D., & Sagawa, K. (1986) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1986.250.6.r1021 · Cited by 405
Mechanical Principles in Arterial Disease
O’Rourke, M. (1995) · Hypertension · doi:10.1161/01.hyp.26.1.2 · Cited by 401
Self-citationEffects of age on ventricular-vascular coupling
Nichols, W. W., O'Rourke, M. F., Avolio, A. P., Yaginuma, T., Murgo, J. P., Pepine, C. J., & Conti, C. R. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)90659-9 · Cited by 346
Self-citationArterial aging: pathophysiological principles
O'Rourke, M. F. (2007) · Vascular Medicine · doi:10.1177/1358863x07083392 · Cited by 275
Self-citationSaba, P. S., Roman, M. J., Pini, R., Spitzer, M., Ganau, A., & Devereux, R. B. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90772-s · Cited by 266
GALLAGHER, D., ADJI, A., & OROURKE, M. (2004) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2004.05.027 · Cited by 194
“” While justifying McDonald’s early approach, the views gained further confirmation from the work of McDonald’s protégé, Michael Taylor, who popularized the concept of vascular impedance through detailed physiologic and theoretical studies.(11,30,31) By 1980, opposition to this basic concept had evaporated.”
MethodSelf-citationKono, A., Maughan, W. L., Sunagawa, K., Hamilton, K., Sagawa, K., & Weisfeldt, M. L. (1984) · Circulation · doi:10.1161/01.cir.70.6.1057 · Cited by 193
Ventriculo-arterial coupling: Concepts, assumptions, and applications
Kass, D. A., & Kelly, R. P. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368505 · Cited by 177
“Since measurements of vascular impedance accurately describe the properties of the vasculature distal to the point of measurement, calculation of ascending aortic input impedance is accepted as being the most complete description of the hydraulic load faced by the left ventricle (33,41).”
BackgroundInfluentialWilkinson, I. B., MacCallum, H., Hupperetz, P. C., van Thoor, C. J., Cockcroft, J. R., & Webb, D. J. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0541k.x · Cited by 174
“However, previous studies have demonstrated that the reflection coefficient is •0·85 under resting conditions (O’Rourke & Taylor, 1967; Nichols et al. 1977; Ting et al. 1991), implying a high degree of wave reflection within the arterial tree but this can be enhanced by infusion of angiotensin II…”
BackgroundStergiopulos, N., Meister, J. J., & Westerhof, N. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368245 · Cited by 173
“However, input impedances of the femoral and carotid beds deviate from those of the three element windkessel model (8).”
MethodGenesis of the normal and abnormal arterial pulse
Vlachopoulos, C., & O'Rourke, M. (2000) · Current Problems in Cardiology · doi:10.1067/mcd.2000.104057 · Cited by 125
Self-citation
Metadata
- Authors
- O'ROURKE, M. F., & TAYLOR, M. G.
- Venue
- Circulation Research
- Published
- 1967-04
- Volume
- 20
- Issue
- 4
- Pages
- 365-380
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W1967118204
- Cited by
- 282
- References
- 11
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.