The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Acute Vascular Endothelial Changes Associated with Increased Blood Velocity Gradients
Open accessAbstract
The purpose of this study is to quantify the acute changes in endothelial histology that are associated with an induced increase in blood velocity. A nontraumatic intra-aortic device was designed to produce a rapid convergence of the aortic blood stream into a narrow channel along the ventral aspect of the thoracic aorta in dogs. The endothelial surface overlying this channel was exposed to a broad range of surface shearing stress by the accelerated blood flow. Techniques were developed to quantify the resulting distribution of shearing stress so that the stress to which the endothelial surface was exposed at every point along the channel could be determined. Special histologic techniques were developed using formalin fixation and gelatin embedding of the tissue so that endothelial cytology could be studied and criteria for normal cells established. Using these criteria, cell counts were done to establish the "normal" endothelial cell population density as a function of stress exposure. The stress corresponding to the mode of these cell density distribution curves was defined as the acute yield stress (τ c ). The acute yield stress for endothelial cells was found to be 379±85 ( SD ) dynes/cm 2 . Exposure to stress in excess of this value for periods as short as one hour resulted in marked deterioration of the endothelial surface consisting of endothelial cytoplasmic swelling, cell deformation, cell disintegration, and finally dissolution and erosion of cell substance. The relationship of these events to cellular rheology and interfacial chemistry is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schlichting, H., & Gersten, K. (2000) · Springer eBooks · doi:10.1007/978-3-642-85829-1 · Cited by 18,700
Cited by
Zarins, C. K., Giddens, D. P., Bharadvaj, B. K., Sottiurai, V. S., Mabon, R. F., & Glagov, S. (1983) · Circulation Research · doi:10.1161/01.res.53.4.502 · Cited by 1,485
A model for the excitation of osteocytes by mechanical loading-induced bone fluid shear stresses
Weinbaum, S., Cowin, S. C., & Zeng, Y. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90010-8 · Cited by 1,277
Haemodynamic shear stress activates a K+ current in vascular endothelial cells
Olesen, S.-P., Claphamt, D., & Davies, P. (1988) · Nature · doi:10.1038/331168a0 · Cited by 1,001
Faggiotto, A., Ross, R., & Harker, L. (1984) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.4.4.323 · Cited by 984
Turbulent fluid shear stress induces vascular endothelial cell turnover in vitro.
Davies, P. F., Remuzzi, A., Gordon, E. J., Dewey, C. F., & Gimbrone, M. A. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.7.2114 · Cited by 847
Adaptive regulation of wall shear stress to flow change in the canine carotid artery
Kamiya, A., & Togawa, T. (1980) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1980.239.1.h14 · Cited by 817
Non-Newtonian blood flow in human right coronary arteries: steady state simulations
Johnston, B. M., Johnston, P. R., Corney, S., & Kilpatrick, D. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.09.016 · Cited by 689
Flow characteristics in models of arterial stenoses — II. Unsteady flow
Young, D. F., & Tsai, F. Y. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90012-2 · Cited by 680
Arterial Wall Shear and Distribution of Early Atheroma in Man
CARO, C. G., FITZ-GERALD, J. M., & SCHROTER, R. C. (1969) · Nature · doi:10.1038/2231159a0 · Cited by 630
Boussel, L., Rayz, V., McCulloch, C., Martin, A., Acevedo-Bolton, G., Lawton, M., Higashida, R., Smith, W. S., Young, W. L., & Saloner, D. (2008) · Stroke · doi:10.1161/strokeaha.108.521617 · Cited by 535
Berger, S. A., & Jou, L.-D. (2000) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.32.1.347 · Cited by 502
Fluid Flow Stimulates Tissue Plasminogen Activator Secretion by Cultured Human Endothelial Cells
Diamond, S. L., Eskin, S. G., & McIntire, L. V. (1989) · Science · doi:10.1126/science.2467379 · Cited by 450
Physical factors in the initiation, growth, and rupture of human intracranial saccular aneurysms
Ferguson, G. G. (1972) · Journal of Neurosurgery · doi:10.3171/jns.1972.37.6.0666 · Cited by 442
MOOREJR, J., XU, C., GLAGOV, S., ZARINS, C., & KU, D. (1994) · Atherosclerosis · doi:10.1016/0021-9150(94)90207-0 · Cited by 425
The distribution of blood rheological parameters in the microvasculature of cat mesentery.
Lipowsky, H. H., Kovalcheck, S., & Zweifach, B. W. (1978) · Circulation Research · doi:10.1161/01.res.43.5.738 · Cited by 408
The Mechanical Behavior of Vascular Grafts: A Review
Salacinski, H. J., Goldner, S., Giudiceandrea, A., Hamilton, G., Seifalian, A. M., Edwards, A., & Carson, R. J. (2001) · Journal of Biomaterials Applications · doi:10.1106/na5t-j57a-jtdd-fd04 · Cited by 399
FRY, D. L. (1969) · Circulation Research · doi:10.1161/01.res.24.1.93 · Cited by 396
Self-citationImage-Based Computational Fluid Dynamics Modeling in Realistic Arterial Geometries
Steinman, D. A. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1467679 · Cited by 381
Increased endothelial cell turnover in areas of in vivo Evans Blue uptake in the pig aorta
Caplan, B. A., & Schwartz, C. J. (1973) · Atherosclerosis · doi:10.1016/0021-9150(73)90031-2 · Cited by 380
Hydrodynamic effects on animal cells grown in microcarrier cultures
Croughan, M. S., Hamel, J., & Wang, D. I. C. (1987) · Biotechnology and Bioengineering · doi:10.1002/bit.260290117 · Cited by 371
Davies, P. F., Dewey, C. F., Bussolari, S. R., Gordon, E. J., & Gimbrone, M. A. (1984) · Journal of Clinical Investigation · doi:10.1172/jci111298 · Cited by 359
Atherosclerosis and arteriosclerosis in chronic renal failure
London, G. M., & Drüeke, T. B. (1997) · Kidney International · doi:10.1038/ki.1997.233 · Cited by 354
Wentzel, J. J., Chatzizisis, Y. S., Gijsen, F. J. H., Giannoglou, G. D., Feldman, C. L., & Stone, P. H. (2012) · Cardiovascular Research · doi:10.1093/cvr/cvs217 · Cited by 353
FLAHERTY, J. T., PIERCE, J. E., FERRANS, V. J., PATEL, D. J., TUCKER, W. K., & FRY, D. L. (1972) · Circulation Research · doi:10.1161/01.res.30.1.23 · Cited by 342
Self-citationCox, J. L., Chiasson, D. A., & Gotlieb, A. I. (1991) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(91)90019-i · Cited by 333
Correlation between intimal thickness and fluid shear in human arteries
Friedman, M. H., Hutchins, G. M., Brent Bargeron, C., Deters, O. J., & Mark, F. F. (1981) · Atherosclerosis · doi:10.1016/0021-9150(81)90027-7 · Cited by 333
McGill, H. C., McMahan, C. A., Herderick, E. E., Tracy, R. E., Malcom, G. T., Zieske, A. W., & Strong, J. P. (2000) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.20.3.836 · Cited by 320
Steady flow in a model of the human carotid bifurcation. Part I—Flow visualization
Bharadvaj, B. K., Mabon, R. F., & Giddens, D. P. (1982) · Journal of Biomechanics · doi:10.1016/0021-9290(82)90057-4 · Cited by 315
London, G. M. (2003) · Seminars in Dialysis · doi:10.1046/j.1525-139x.2003.16023.x · Cited by 307
Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: a review
Haruguchi, H., & Teraoka, S. (2003) · Journal of Artificial Organs · doi:10.1007/s10047-003-0232-x · Cited by 303
Nabel, E. G., Selwyn, A. P., & Ganz, P. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90584-c · Cited by 296
Hemodynamic Shear Stresses in Mouse Aortas: Implications for Atherogenesis
Suo, J., Ferrara, D. E., Sorescu, D., Guldberg, R. E., Taylor, W. R., & Giddens, D. P. (2007) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000253492.45717.46 · Cited by 294
Mass Transport in Arteries and the Localization of Atherosclerosis
Tarbell, J. M. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121529 · Cited by 281
Milner, J. S., Moore, J. A., Rutt, B. K., & Steinman, D. A. (1998) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(98)70210-1 · Cited by 276
The shear stress of it all: the cell membrane and mechanochemical transduction
White, C. R., & Frangos, J. A. (2007) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2007.2128 · Cited by 255
Flow patterns in the human carotid artery bifurcation.
Motomiya, M., & Karino, T. (1984) · Stroke · doi:10.1161/01.str.15.1.50 · Cited by 254
Mechanical effects on endothelial cell morphology: In vitro assessment
Ives, C. L., Eskin, S. G., & McIntire, L. V. (1986) · In Vitro Cellular & Developmental Biology · doi:10.1007/bf02621134 · Cited by 253
Vascular Dynamics of a Shape Memory Polymer Foam Aneurysm Treatment Technique
Ortega, J., Maitland, D., Wilson, T., Tsai, W., Savaş, Ö., & Saloner, D. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9358-y · Cited by 57
Metadata
- Authors
- FRY, D. L.
- Venue
- Circulation Research
- Published
- 1968-02
- Volume
- 22
- Issue
- 2
- Pages
- 165-197
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W1986161881
- Cited by
- 1,238
- References
- 1
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.