Measurement of Viscoelastic Properties of Arteries in the Living Dog
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Dynamic elastic moduli (E dyn ) and viscous moduli (ηω) of the arterial wall were obtained at a number of sites of the systemic vascular tree of living dogs anesthetized with pentobarbital. Constants were calculated using the first harmonics of pressure and diameter obtained from a Fourier analysis of simultaneously recorded pulse waves. The means and standard errors of E dyn , in dynes cm -2 x 10 6 , obtained at mean blood pressures ranging from 87 to 130 mm Hg and pulse frequencies from 1.1 to 2.8 cps were: 3.0±0.33 (9 midthoracic aortas), 9.8±1.2 (7 midabdominal aortas), 11.0 (4 iliac arteries), and 12.3±1.2 (11 femoral arteries). The viscous modulus was approximately 9% of E dyn in the midthoracic aorta and approximately 12% of E dyn in the abdominal and femoral arteries. Pulse wave velocities calculated from values of E dyn and relative wall thickness by the Moens-Korteweg equation agreed with accepted values. A Fourier analysis of pressure and diameter waves was shown to be unsatisfactory for determining the frequency dependence of viscoelastic constants because of anomalous behavior of the viscoelastic parameters. In the midthoracic aorta this behavior may have been partly attributable to artefact; however, there was strong evidence that elsewhere nonlinear pressure and diameter relationships interfered with the accurate determination of the relatively small, higher-order harmonic components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanical Properties of Arteries in Vivo
PETERSON, L. H., JENSEN, R. E., & PARNELL, J. (1960) · Circulation Research · doi:10.1161/01.res.8.3.622 · Cited by 679
Cited by
Introductory biomechanics: from cells to organisms
(2007) · Choice Reviews Online · doi:10.5860/choice.45-1476 · Cited by 241
Isnard, R. N., Pannier, B. M., Laurent, S., London, G. M., Diebold, B., & Safar, M. E. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90518-4 · Cited by 235
Pulse Wave Velocity as a Measure of Blood Pressure Change
Gribbin, B., Steptoe, A., & Sleight, P. (1976) · Psychophysiology · doi:10.1111/j.1469-8986.1976.tb03344.x · Cited by 225
Kanai, H. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1561662 · Cited by 213
“About 2 Hz 290–1,460 kPa 2,800–19,000 Pa·s Canine descending thoracic [43]”
Measurements of Young's modulus of elasticity of the canine aorta with ultrasound
Hughes, D. (1979) · Ultrasonic Imaging · doi:10.1016/0161-7346(79)90028-2 · Cited by 189
Arterial viscoelasticity: A generalized model
Westerhof, N., & Noordergraaf, A. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90036-9 · Cited by 171
Metadata
- Authors
- GOW, B. S., & TAYLOR, M. G.
- Venue
- Circulation Research
- Published
- 1968-07
- Volume
- 23
- Issue
- 1
- Pages
- 111-122
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2085069224
- Cited by
- 209
- References
- 1
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.