The DOI matches its Crossref record.
Pulse Wave Velocity as a Measure of Blood Pressure Change
Abstract
The use of arterial pulse wave velocity (PWV) as a continuous measure of blood pressure changes is outlined. Theoretical considerations indicate that changes in PWV reflect changes in blood pressure, and an experiment was carried out to assess this relationship. PWV along an arm artery was monitored in 26 subjects at a time when the arterial distending pressure of the limb was altered over a wide range by means of externally applied positive and negative pressures. The results show that changes in PWV reliably follow changes in blood pressure. This method can be considered suitable for studies requiring changes rather than absolute values of blood pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“…respect to time between the diastolic minimum and maximum first derivative with respect to time [134]; 3) a fraction of the pulse pressure [49], [135]; and (d) the intersection of the horizontal line through the minimum and the tangent line fitted through points near the maximum first derivative…”
BackgroundChen, W., Kobayashi, T., Ichikawa, S., Takeuchi, Y., & Togawa, T. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345755 · Cited by 425
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418
Gottman, J. M., Jacobson, N. S., Rushe, R. H., & Shortt, J. W. (1995) · Journal of Family Psychology · doi:10.1037/0893-3200.9.3.227 · Cited by 363
Pulse Transit Time as an Indicator of Arterial Blood Pressure
Geddes, L. A., Voelz, M. H., Babbs, C. F., Bourland, J. D., & Tacker, W. A. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb01545.x · Cited by 293
Metadata
- Authors
- Gribbin, B., Steptoe, A., & Sleight, P.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1976-01
- Volume
- 13
- Issue
- 1
- Pages
- 86-90
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W1994171917
- Cited by
- 225
- References
- 0
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulse Wave Velocity as a Measure of Blood Pressure Change. https://app.cochat.ai/papers/10.1111/j.1469-8986.1976.tb03344.x
- The paper
- Gribbin, B., Steptoe, A., & Sleight, P. (1976). Pulse Wave Velocity as a Measure of Blood Pressure Change. Psychophysiology. https://doi.org/10.1111/j.1469-8986.1976.tb03344.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.