Cited by 21Tissue Engineering and Regenerative Medicine3D Printing in Biomedical ResearchMechanical Circulatory Support Devices

The bioengineered cardiac left ventricle

Patel, Nikita M., Birla, Ravi K.·2018·ASAIO Journal

Abstract

Left ventricle and aortic valve underdevelopment are presentations in the congenital cardiac condition hypoplastic left heart syndrome (HLHS); current clinical treatments involve right ventricle refunctionalization. Cardiac organoid models provide simplified open chambers engineered into a flow loop, to ameliorate ventricle-type function. Complete bioengineered ventricle development presents a significant advancement in cardiac organoids. This study provides the foundation for bioengineered complete ventricle (BECV) fabrication. Bioengineered trileaflet valve (BETV) molds and chitosan scaffolds were developed to emulate human neonate aortic valve geometry. Bioengineered complete ventricle were fabricated by fitting BETV into a bioengineered open ventricle (BEOV); the chamber was cellularized using a two-stage cellularization strategy, and BETV were passively seeded with rat neonatal cardiac fibroblasts and perfusion cultured for 3 days. Average pressure generated ranged from 0.06 to 0.12 mm Hg; average biopotential output was 1.02 mV. Histologic assessment displayed syncytial-type cardiomyocyte aggregates at the BECV chamber surface; BETV displayed randomly oriented, diffusely distributed cardiac fibroblasts. The fabrication of this novel BECV may aid in developing a functional engineered left ventricle for clinical application in HLHS.

Integrity signals

Registry

Crossref · 10.1097/mat.0000000000000642

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • These methods oftentimes involve scaffolds which might interfere with tissue properties.

    “In addition, these methods oftentimes involve scaffolds which might interfere with tissue properties (Patel and Birla, 2018; Chang et al., 2022; Choi et al., 2023; MacQueen et al., 2018; Michas et al., 2022; Xie et al., 2023; Williams et al., 2025).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Patel, N. M., & Birla, R. K.
Affiliations
University of Houston (US)
Corresponding author
Birla, Ravi K.
Venue
ASAIO Journal
Published
2018-01
Volume
64
Issue
1
Pages
56-62
ISSN
1058-2916 (ISSN-L)
OpenAlex
W2750710355
Cited by
20
References
25
Citations by year
2026: 3 · 2025: 2 · 2024: 3 · 2023: 2 · 2022: 3 · 2021: 3 · 2020: 4
FWCI
1.12
Type
journal article
Language
en
Open access
closed
Locations
  • ASAIO Journal (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Mechanical Circulatory Support Devices
Keywords
hypoplastic left heart syndrome, cardiac organoids, trileaflet valve, chitosan scaffolds, aortic valve, perfusion culture
MeSH terms
Animals, Aortic Valve, Heart Ventricles, Humans, Infant, Newborn, Ventricular Function, Hypoplastic Left Heart Syndrome, Cell Culture Techniques, Myocytes, Cardiac, Chitosan, Rats, Bioengineering

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review