Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 174

The DOI matches its Crossref record.

Vascular endothelium-leukocyte interaction; sticking shear force in venules.

Schmid-Schoenbein, G W, Fung, Y C, Zweifach, B W·1975·Circulation Research

Abstract

To determine the shear force acting on a white blood cell sticking to the endothelium of a blood vessel, the flow field about a single white blood cell in a venule was determined by hign-speed motion picture photomicrography. The force acting on the white blood cell was then calculated according to the principles of fluid mechanics. In this paper, the calculation was made using an experimentally determined dimensionless shear force coefficient obtained from a kinematically and dynamically similar model. The large physical model of the hemodynamic system could be easily instrumented, and the shear force acting on the model cell and the flow field around it were measured. The data were then used to calculate a shear force coefficient. On the basis of dynamic similarity, this shear force coefficient was applied to the white blood cell in the venule. The shear force coefficient was strongly influenced by the hematocrit, so in vivo hematocrits were measured from electron micrographs. It was found that in the venules of the rabbit omentum a white blood cell sticking to the endothelial wall was subjected to a shear force in the range of 4 times 10--5 dynes to 234 times 10--5 dynes; the exact value depended on the size and motion of the white blood cell, the size of the blood vessel, the velocity of the blood flow, and the local hematocrit, which varied between 20% and 40% in venules of about 40 mum in diameter. The contact area between the white blood cell and the endothelial cell was estimated, and the shear stress was found to range between 50 dynes/cm-2 and 1060 dynes/cm-2. The normal stress of interaction between the white blood cell and the endothelium had a maximum value that was of the same order of magnitude as the shear stress. The accumulated relative error of the experimental procedure was about 49%. The instantaneous shear force was a random function of time because of random fluctuations of the hematocrit.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.36.1.173

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 174

Metadata

Authors
Schmid-Schoenbein, G. W., Fung, Y. C., & Zweifach, B. W.
Venue
Circulation Research
Published
1975-01
Volume
36
Issue
1
Pages
173-184
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2001718528
Cited by
174
References
0
FWCI
3.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vascular endothelium-leukocyte interaction; sticking shear force in venules. https://app.cochat.ai/papers/10.1161/01.res.36.1.173
The paper
Schmid-Schoenbein, G. W., Fung, Y. C., & Zweifach, B. W. (1975). Vascular endothelium-leukocyte interaction; sticking shear force in venules. Circulation Research. https://doi.org/10.1161/01.res.36.1.173

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.