The DOI matches its Crossref record.
Fluid dynamics of coronary artery stenosis.
Open accessAbstract
A large-scale model of the coronary circulation, instrumented to permit detailed pressure and velocity measurements, has been used to study flow through isolated stenotic elements in large coronary arteries. Pulsatile aortic and instantaneous peripheral resistance were stimulated with servovalves. A variety of axisymmetric and asymmetric stenoses were studied and flow separation was found to occur for all but very mild stenoses. Pressure recovery downstream of the stenosis throat was limited and, in some cases, no recovery was observed. Pressure drop was primarily dependent upon the minimum area of the stenosis and relatively independent of stenosis geometry. Flow was quasi-steady at normal heart rates, and simple steady flow theory proved adequate to describe the pressure drop through the stenosis. The theory yielded results that agreed well with published data for dogs and appears promising for predicting effects of hemodynamic variables on a given stenotic lesion. Thus, principal findings of the study are that a relatively severe stenosis behaves essentially like an orifice and that a simple quasi-steady theory appears adequate to predict effects of a stenosis on coronary flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gould, K. L. (1978) · Circulation Research · doi:10.1161/01.res.43.2.242 · Cited by 368
Reconstruction of Brachial Artery Pressure From Noninvasive Finger Pressure Measurements
Bos, W. J. W., van Goudoever, J., van Montfrans, G. A., van den Meiracker, A. H., & Wesseling, K. H. (1996) · Circulation · doi:10.1161/01.cir.94.8.1870 · Cited by 365
Kirkeeide, R. L., Gould, K. L., & Parsel, L. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80266-2 · Cited by 325
Demer, L. L., Gould, K. L., Goldstein, R. A., Kirkeeide, R. L., Mullani, N. A., Smalling, R. W., Nishikawa, A., & Merhige, M. E. (1989) · Circulation · doi:10.1161/01.cir.79.4.825 · Cited by 316
Serruys, P. W., Reiber, J. H. C., Wijns, W., Brand, M. V. D., Kooijman, C. J., ten Katen, H. J., & Hugenholtz, P. G. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90235-2 · Cited by 271
Metadata
- Authors
- Mates, R. E., Gupta, R. L., Bell, A. C., & Klocke, F. J.
- Venue
- Circulation Research
- Published
- 1978-01
- Volume
- 42
- Issue
- 1
- Pages
- 152-162
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2126268458
- Cited by
- 196
- References
- 0
- FWCI
- 11.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluid dynamics of coronary artery stenosis. https://app.cochat.ai/papers/10.1161/01.res.42.1.152
- The paper
- Mates, R. E., Gupta, R. L., Bell, A. C., & Klocke, F. J. (1978). Fluid dynamics of coronary artery stenosis. Circulation Research. https://doi.org/10.1161/01.res.42.1.152
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.