Inhibitors of oxidative ATP production cause transient vasoconstriction and block subsequent pressor responses in rat lungs.
The DOI matches its Crossref record.
Abstract
We wondered if depression of oxidative adenosine triphosphate (ATP) production caused pulmonary vasoconstriction. If so, then several chemically different inhibitors of oxidative ATP production all should cause pulmonary pressor responses. The vascular reactivity of isolated, blood-perfused rat lungs was established by eliciting pressor responses to airway hypoxia and to intraarterial angiotensin II. Then, during normoxia, we added to perfusate one of five chemical inhibitors of oxidative ATP production: 10 mM azide, 1 mM cyanide, 1 mM dinitrophenol, 5 or 10 microM antimycin A, or 0.5 microM rotenone. Each of the five chemical inhibitors, but not their solvents, caused a transient pressor response, followed by loss of vascular reactivity to hypoxia, angiotensin II, and chemical inhibitors. The inhibitor pressor responses were not due to an effect on blood cells, since they also were seen in lungs perfused with plasma. The magnitudes of pressor responses to all metabolic inhibitors except azide correlated with the magnitudes of preceding pressor responses to hypoxia, but not to the preceding angiotensin II responses. When verapamil or calcium chloride was added to perfusate, the hypoxic and inhibitor pressor responses were blunted more than was the angiotensin II response. Thus, five chemically different substances, inhibiting different steps of oxidative ATP production, all caused pressor responses that were blocked readily by verapamil and by increased perfusate calcium chloride. These results support the possibility that depression of oxidative ATP production elicits pulmonary vasoconstriction that is dependent on influx of extracellular calcium. Hypoxia might also be sensed in the pulmonary circulation by decreased oxidative ATP production in some as yet unidentified lung cell.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hypoxic Pulmonary Vasoconstriction
Sylvester, J. T., Shimoda, L. A., Aaronson, P. I., & Ward, J. P. T. (2012) · Physiological Reviews · doi:10.1152/physrev.00041.2010 · Cited by 725
Hypoxic Pulmonary Vasoconstriction
Dunham-Snary, K. J., Wu, D., Sykes, E. A., Thakrar, A., Parlow, L. R. G., Mewburn, J. D., Parlow, J. L., & Archer, S. L. (2017) · Chest · doi:10.1016/j.chest.2016.09.001 · Cited by 510
Hypoxic pulmonary vasoconstriction
Moudgil, R., Michelakis, E. D., & Archer, S. L. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00733.2004 · Cited by 454
Model for Hypoxic Pulmonary Vasoconstriction Involving Mitochondrial Oxygen Sensing
Waypa, G. B., Chandel, N. S., & Schumacker, P. T. (2001) · Circulation Research · doi:10.1161/hh1201.091960 · Cited by 367
Archer, S. L., Gomberg-Maitland, M., Maitland, M. L., Rich, S., Garcia, J. G. N., & Weir, E. K. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01324.2007 · Cited by 366
Metadata
- Authors
- Rounds, S., & McMurtry, I. F.
- Venue
- Circulation Research
- Published
- 1981-03
- Volume
- 48
- Issue
- 3
- Pages
- 393-400
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2132623108
- Cited by
- 103
- References
- 0
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inhibitors of oxidative ATP production cause transient vasoconstriction and block subsequent pressor responses in rat lungs. https://app.cochat.ai/papers/10.1161/01.res.48.3.393
- The paper
- Rounds, S., & McMurtry, I. F. (1981). Inhibitors of oxidative ATP production cause transient vasoconstriction and block subsequent pressor responses in rat lungs. Circulation Research. https://doi.org/10.1161/01.res.48.3.393
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.