CoChat

Dynamic ventricular interaction in the conscious dog.

Olsen, C O, Tyson, G S, Maier, G W, Spratt, J A, Davis, J W, Rankin, J S · 1983 · Circulation Research
Cited by 173

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

In nine conscious, chronically instrumented dogs, ultrasonic dimension transducers measured left ventricular anterior-posterior and septal-free wall minor axis and major axis diameters. Matched micromanometers measured right and left ventricular transmural and transeptal pressures. Ventricular pressures and volumes were varied by inflation of implanted vena caval and pulmonary artery occluders, and the functional significance of the two types of ventricular interaction, i.e., direct and series, was determined. The left ventricle was represented by a modified ellipsoidal geometry. Left ventricular stroke volume calculated from the dimension data correlated well with that measured directly from ascending aortic electromagnetic flow probes during all interventions (r greater than or equal to 0.96). Partial pulmonary artery occlusion significantly increased right ventricular diastolic and systolic pressures as compared to values obtained during control and venal caval occlusion. During pulmonary artery occlusion, latitudinal septal eccentricity was increased throughout the cardiac cycle compared to control and vena caval occlusion (P less than 0.05), indicating leftward interventricular septal shifting and significant alteration of left ventricular shape. The normalized diastolic pressure-volume curve was shifted to the left with pulmonary artery occlusion compared to control and indicated a decrease in left ventricular chamber compliance. However, when selected cardiac cycles with similar end-diastolic volumes from vena caval and pulmonary artery occlusions were compared, parameters of left ventricular systolic function (stroke volume, percent systolic shortening, peak aortic blood flow, peak left ventricular pressure, and its first derivative) remained relatively constant. These data suggest that mean myocardial fiber length is the major preload determinant of left ventricular systolic function independent of chamber pressure and shape, and that direct ventricular interaction mediated by interventricular septal shifting has minimal effects on systolic myocardial performance in this model. Thus, series ventricular interaction during acute imbalances in biventricular loading, where the output of the right ventricle determines the input of the left, seems to be far more important than direct interaction to the regulation of overall cardiac function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.52.1.85

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

Metadata

Authors
Olsen, C. O., Tyson, G. S., Maier, G. W., Spratt, J. A., Davis, J. W., & Rankin, J. S.
Venue
Circulation Research
Published
1983-01
Volume
52
Issue
1
Pages
85-104
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2067817449
Cited by
173
References
17
FWCI
8.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.