Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 632

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Balloon angioplasty. Natural history of the pathophysiological response to injury in a pig model.

Steele, P M, Chesebro, J H, Stanson, A W, Holmes, D R, Dewanjee, M K, Badimon, L, Fuster, V·1985·Circulation Research

Abstract

The restenosis or occlusion that frequently follows balloon angioplasty is poorly understood. Thus, the pathophysiological response to angioplasty of the common carotid artery in 38 heparinized normal pigs was investigated by quantification of the 111In-labeled platelet deposition and histological and electron microscopic examination from 1 hour to 60 days after angioplasty. At 1 hour, the following findings were noted: complete endothelial denudation in all arteries, marked platelet deposition (44.7 +/- 20.7 X 10(6)/cm2), mural thrombus in seven of 10 pigs, and a medial tear extending through the internal elastic lamina in nine of 18 arteries. All nine arteries with tears had associated mural thrombus and severe platelet deposition (76 X 10(6)/cm2); in contrast, the nine arteries without a tear had no mural thrombus and much lower platelet deposition (6 X 10(6)/cm2). Necrosis of medial smooth muscle cells was evident at 24 hours. Platelet deposition remained high at 24 hours (40.5 +/- 20.6 X 10(6)/cm2), but was markedly reduced at 4 days (4.4 +/- 1.5 X 10(6)/cm2), coincident with partial regrowth of endothelium or periluminal lining cells. No significant platelet deposition was noted at 7 days, when the endothelial cell type of regrowth was largely complete. Intimal proliferation of smooth muscle cells was mild and patchy at 7 days, significantly greater and more uniform at 14 days, and unchanged at 30 and 60 days after angioplasty. Complete thrombotic occlusion occurred in four (11%) of the 38 pigs. A significant stenosis present at 30 days after angioplasty was shown by histological examination to be due to organization of mural thrombus.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.57.1.105

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 632

Metadata

Authors
Steele, P. M., Chesebro, J. H., Stanson, A. W., Holmes, D. R., Dewanjee, M. K., Badimon, L., & Fuster, V
Venue
Circulation Research
Published
1985-07
Volume
57
Issue
1
Pages
105-112
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2159642184
Cited by
632
References
11
FWCI
22.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Balloon angioplasty. Natural history of the pathophysiological response to injury in a pig model. https://app.cochat.ai/papers/10.1161/01.res.57.1.105
The paper
Steele, P. M., Chesebro, J. H., Stanson, A. W., Holmes, D. R., Dewanjee, M. K., Badimon, L., & Fuster, V. (1985). Balloon angioplasty. Natural history of the pathophysiological response to injury in a pig model. Circulation Research. https://doi.org/10.1161/01.res.57.1.105

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.